- Back Home >
- Products >
- Power Cable >
- 2PNCT
2PNCT
Products
2PNCT
600V Second Type EPR (Ethylene Propylene Rubber) Insulated Neoprene Sheathed Flexible Cables (2PNCT). It shall comply with the standard of CNS 10741.
Features
Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: EPR (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: Neoprene Introduction: The 2PNCT portable Cable with flexible conductor is used for Electric Machinery and Apparatus. The EPR insulated Neoprene (Polyvinyl Chloride) sheathed portable cable has excellent flexibility. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties.
Specifications
600V 2PNCT SINGLE CORE CABLE Refer to CNS 10741
Conductor | Thickness of insulation mm | Approx.Overall Diameter mm | Approx.Weight Kg/km | StandardLength M | ||
---|---|---|---|---|---|---|
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer DiameterApprox. mm | ||||
0.75 | 30/0.18 | 1.1 | 0.8 | 5.8 | 48 | 200 |
1.25 | 50/0.18 | 1.5 | 0.8 | 6.2 | 60 | 200 |
2.0 | 37/0.26 | 1.8 | 0.8 | 6.5 | 70 | 200 |
3.5 | 45/0.32 | 2.5 | 0.8 | 7.4 | 95 | 200 |
5.5 | 70/0.32 | 3.1 | 1.0 | 8.4 | 130 | 200 |
8 | 50/0.45 | 3.7 | 1.0 | 9.2 | 165 | 200 |
14 | 88/0.45 | 4.9 | 1.0 | 11.0 | 240 | 200 |
22 | 7/20/0.45 | 7.0 | 1.2 | 13.5 | 375 | 200 |
30 | 7/27/0.45 | 8.1 | 1.2 | 15.0 | 470 | 200 |
38 | 7/34/0.45 | 9.1 | 1.2 | 16.0 | 570 | 200 |
50 | 19/16/0.45 | 10.4 | 1.5 | 18.0 | 720 | 200 |
60 | 19/20/0.45 | 11.6 | 1.5 | 19.5 | 870 | 200 |
80 | 19/27/0.45 | 13.5 | 2.0 | 23 | 1180 | 200 |
100 | 19/34/0.45 | 15.2 | 2.0 | 25 | 1430 | 200 |
600V 2PNCT TWO CORE CABLE Refer to CNS 10741
Conductor | Thickness of insulation mm | Approx.Overall Diameter mm | Approx.Weight Kg/km | StandardLength M | ||
---|---|---|---|---|---|---|
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer DiameterApprox. mm | ||||
0.75 | 30/0.18 | 1.1 | 0.8 | 9.0 | 115 | 200 |
1.25 | 50/0.18 | 1.5 | 0.8 | 9.8 | 140 | 200 |
2.0 | 37/0.26 | 1.8 | 0.8 | 11.0 | 175 | 200 |
3.5 | 45/0.32 | 2.5 | 0.8 | 12.5 | 245 | 200 |
5.5 | 70/0.32 | 3.1 | 1.0 | 14.5 | 350 | 200 |
8 | 50/0.45 | 3.7 | 1.0 | 16.0 | 435 | 200 |
14 | 88/0.45 | 4.9 | 1.0 | 18.5 | 640 | 200 |
22 | 7/20/0.45 | 7.0 | 1.2 | 25 | 1070 | 200 |
30 | 7/27/0.45 | 8.1 | 1.2 | 27 | 1340 | 200 |
38 | 7/34/0.45 | 9.1 | 1.2 | 30 | 1630 | 200 |
50 | 19/16/0.45 | 10.4 | 1.5 | 34 | 2100 | 200 |
60 | 19/20/0.45 | 11.6 | 1.5 | 37 | 2520 | 200 |
80 | 19/27/0.45 | 13.5 | 2.0 | 43 | 3470 | 200 |
100 | 19/34/0.45 | 15.2 | 2.0 | 47 | 4200 | 200 |
600V 2PNCT THREE CORE CABLE Refer to CNS 10741
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
---|---|---|---|---|---|---|
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
0.75 | 30/0.18 | 1.1 | 0.8 | 10.5 | 160 | 200 |
1.25 | 50/0.18 | 1.5 | 0.8 | 11.5 | 195 | 200 |
2.0 | 37/0.26 | 1.8 | 0.8 | 12.5 | 245 | 200 |
3.5 | 45/0.32 | 2.5 | 0.8 | 14.5 | 355 | 200 |
5.5 | 70/0.32 | 3.1 | 1.0 | 17.0 | 515 | 200 |
8 | 50/0.45 | 3.7 | 1.0 | 18.5 | 655 | 200 |
14 | 88/0.45 | 4.9 | 1.0 | 22 | 1000 | 200 |
22 | 7/20/0.45 | 7.0 | 1.2 | 29 | 1670 | 200 |
30 | 7/27/0.45 | 8.1 | 1.2 | 32 | 2100 | 200 |
38 | 7/34/0.45 | 9.1 | 1.2 | 35 | 2550 | 200 |
50 | 19/16/0.45 | 10.4 | 1.5 | 40 | 3320 | 200 |
60 | 19/20/0.45 | 11.6 | 1.5 | 44 | 4020 | 200 |
80 | 19/27/0.45 | 13.5 | 2.0 | 51 | 5500 | 200 |
100 | 19/34/0.45 | 15.2 | 2.0 | 56 | 6720 | 200 |
600V 2PNCT FOUR CORE CABLE Refer to CNS 10741
Conductor | Thickness of insulation mm | Approx.Overall Diameter mm | Approx.Weight Kg/km | StandardLength M | ||
---|---|---|---|---|---|---|
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer DiameterApprox. mm | ||||
0.75 | 30/0.18 | 1.1 | 0.8 | 9.4 | 130 | 200 |
1.25 | 50/0.18 | 1.5 | 0.8 | 10.5 | 175 | 200 |
2.0 | 37/0.26 | 1.8 | 0.8 | 11.5 | 200 | 200 |
3.5 | 45/0.32 | 2.5 | 0.8 | 13.0 | 290 | 200 |
5.5 | 70/0.32 | 3.1 | 1.0 | 15.5 | 415 | 200 |
8 | 50/0.45 | 3.7 | 1.0 | 17.0 | 525 | 200 |
14 | 88/0.45 | 4.9 | 1.0 | 20 | 795 | 200 |
22 | 7/20/0.45 | 7.0 | 1.2 | 27 | 1330 | 200 |
30 | 7/27/0.45 | 8.1 | 1.2 | 29 | 1670 | 200 |
38 | 7/34/0.45 | 9.1 | 1.2 | 32 | 2020 | 200 |
50 | 19/16/0.45 | 10.4 | 1.5 | 36 | 2620 | 200 |
60 | 19/20/0.45 | 11.6 | 1.5 | 39 | 3150 | 200 |
80 | 19/27/0.45 | 13.5 | 2.0 | 46 | 4320 | 200 |
100 | 19/34/0.45 | 15.2 | 2.0 | 50 | 5270 | 200 |
更多商品
XLPE69KV
69KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables. It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A007. Features Construction:(1) Conductor: untinned soft annealed stranded copper wires (2) Conductor screen (3) Insulation: XLPE. (4) Insulation screen (5) Copper wires screen (6) Binding tape wraping (7) Sheath: PVC Introduction: The 69KV power cable is apply at high voltage transmission and distribution of electrical energy.The 69KV extra high-voltage XLPE power cable have developed successfully in 1992.The 69KV XLPE power cable has certified by Taiwan Power Company in 1993.The laying off and jointing work of 69KV XLPE power cable has qualified by Taiwan Power Company in 1995. Specifications 69KV XLPE Insulated and PVC Sheathed Power Cable Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Shape Of Conductor Outer Diameter Approx. mm 100 Round Compact 12.0 16.51 63.0 5000 250 150 14.7 16.51 65.5 5700 250 200 17.0 16.51 68.0 6250 250 250 19.0 16.51 70.5 6950 250 325 21.7 16.51 73.5 7800 250 400 24.1 16.51 76.0 8700 250 500 26.9 16.51 79.5 9900 250 600 29.5 16.51 82.5 11150 250 800 4or 5 segmental 34.0 16.51 88.5 13350 250 1000 38.0 16.51 92.0 15350 250 1200 41.7 16.51 96.5 17400 250 1400 45.0 16.51 99.5 19500 250 1600 48.2 16.51 103.0 21460 250XLPE161KV
161KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables. It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A046. Features Construction:(1) Conductor: untinned soft annealed stranded copper wires (2) Conductor screen (3) Insulation: XLPE. (4) Insulation screen (5) Copper wires screen (6) Binding tape and Metal tape wraping (7) Sheath: PVC Introduction: The 161KV power cable is apply at high voltage transmission and distribution of electrical energy.The 161KV extra high-voltage XLPE power cable have developed successfully in 1992. The laying off and jointing work of 161KV XLPE power cable has qualified by Taiwan Power Company in 1997.The 161KV XLPE power cable has certified by Taiwan Power Company in 1999.Pass the 365days long-term cycling test of 161KV extra high-voltage power cable approved by Taiwan Power Company. Specifications 161KV XLPE Insulated and PVC Sheathed Power Cable Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Shape Of Conductor Outer Diamete rApprox. mm 200 Round Compact 17.0 23 84.0 9460 250 250 19.0 23 86.0 10200 250 325 21.7 23 88.7 11100 250 400 24.1 23 91.1 12060 250 500 26.9 23 93.9 13110 250 600 29.5 23 97.5 14650 250 800 4or 5 segmental 34.0 23 104.0 17020 250 1000 38.0 23 109.0 19370 250 1200 41.7 23 111.7 21520 250 1400 45.0 23 116.0 23700 250 1600 48.2 23 119.2 25740 250 1800 51.0 23 123.0 28080 250 2000 53.8 23 125.8 30200 250VV
600V Grade Polyvinyl Chloride Insulated and Sheathed Cables (Code designation: VV). It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 3301. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated power cable has labeled our National Quality Standard. Specifications 600V Single Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 2.3 5.6 40 300 - 1/1.2 1.2 2.3 5.8 45 300 - 1/1.6 1.6 2.3 6.2 60 300 - 1/2.0 2.0 2.3 6.6 85 300 - 1/2.6 2.6 2.5 7.6 105 300 - 1/3.2 3.2 2.7 8.6 140 300 2.0 7/0.6 1.8 2.3 6.4 65 300 3.5 7/0.8 2.4 2.3 7.0 85 300 5.5 7/1.0 3.0 2.5 8.0 115 300 8 7/1.2 3.6 2.7 9.0 155 300 8 * 3.4 2.7 8.8 150 300 14 7/1.6 4.8 2.9 11.0 235 300 14 * 4.4 2.9 10.5 225 300 22 7/2.0 6.0 3.1 12.5 335 300 22 * 5.5 3.1 12.0 325 300 30 7/2.3 6.9 3.1 13.0 410 300 30 * 6.4 3.1 12.5 400 300 38 7/2.6 7.8 3.3 14.5 515 300 38 * 7.3 3.3 14.0 505 300 50 19/1.8 9.0 3.3 16.0 625 300 50 * 8.4 3.3 15.0 600 300 60 19/2.0 10.0 3.3 17.0 750 300 60 * 9.3 3.3 16.0 725 300 80 19/2.3 11.5 3.5 18.5 960 300 80 * 10.7 3.5 17.5 935 300 100 19/2.6 13.0 3.5 20.0 1270 300 100 * 12.0 3.5 19.0 1150 300 125 19/2.9 14.5 3.8 23.0 1440 300 125 * 13.5 3.7 22.0 1400 300 150 37/2.3 16.1 3.8 24 1760 300 150 * 14.7 3.8 23 1660 300 200 37/2.6 18.2 4.1 27 2220 200 200 * 17.0 4.1 26 2170 200 250 61/2.3 20.7 4.2 30 2810 200 250 * 19.0 4.2 28 2670 200 325 61/2.6 23.4 4.5 33 3550 150 325 * 21.7 4.5 31 3430 150 400 61/2.9 26.1 4.7 36 4360 150 400 * 24.1 4.6 34 4160 150 500 61/3.2 28.8 5.0 39 5290 100 500 * 25.9 4.9 37 5200 100 * Compacted stranded conductor 600V TWO-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 8.7 85 300 - 1/1.2 1.2 0.8 9.1 95 300 - 1/1.6 1.6 0.8 9.9 130 300 - 1/2.0 2.0 0.8 11.0 160 300 - 1/2.6 2.6 1.0 13.0 240 200 - 1/3.2 3.2 1.2 15.0 335 150 2.0 7/0.6 1.8 0.8 10.5 135 300 3.5 7/0.8 2.4 0.8 11.5 180 200 5.5 7/1.0 3.0 1.0 13.5 260 150 8 7/1.2 3.6 1.2 15.5 360 150 8 * 3.4 1.2 15.5 330 300 14 7/1.6 4.8 1.4 19.0 555 300 14 * 4.4 1.4 18.0 505 300 22 7/2.0 6.0 1.6 23 815 300 22 * 5.5 1.6 21 730 300 30 7/2.3 6.9 1.6 24 935 300 30 * 6.4 1.6 23 925 300 38 7/2.6 7.8 1.8 27 1250 300 38 * 7.3 1.8 26 1170 300 50 19/1.8 9.0 1.8 29 1520 300 50 * 8.4 1.8 28 1440 300 60 19/2.0 10.0 1.8 32 1820 300 60 * 9.3 1.8 31 1700 300 80 19/2.3 11.5 2.0 36 2360 300 80 * 10.7 2.0 34 2240 300 100 19/2.6 13.0 2.0 39 2900 300 100 * 12.0 2.0 37 2680 300 125 19/2.9 14.5 2.2 43 3500 300 125 * 13.5 2.2 41 3340 300 150 37/2.3 16.1 2.2 47 4100 300 150 * 14.7 2.2 44 3870 300 200 37/2.6 18.2 2.4 52 5170 200 200 * 17.0 2.4 50 5090 200 250 61/2.3 20.7 2.4 58 6530 200 250 * 19.0 2.4 54 6210 200 325 61/2.6 23.4 2.6 64 8230 150 325 * 21.7 2.6 61 8000 150 *Compacted stranded conductor 600V THREE-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 9.1 100 300 - 1/1.2 1.2 0.8 9.5 120 300 - 1/1.6 1.6 0.8 10.5 155 200 - 1/2.0 2.0 0.8 11.5 200 150 - 1/2.6 2.6 1.0 13.5 305 150 - 1/3.2 3.2 1.2 16.0 435 300 2.0 7/0.6 1.8 0.8 11.0 165 200 3.5 7/0.8 2.4 0.8 12.5 235 200 5.5 7/1.0 3.0 1.0 14.5 335 150 8 7/1.2 3.6 1.2 16.5 465 300 8 * 3.4 1.2 16.0 435 300 14 7/1.6 4.8 1.4 20 740 300 14 * 4.4 1.4 19 670 300 22 7/2.0 6.0 1.6 24 1070 300 22 * 5.5 1.6 23 1000 300 30 7/2.3 6.9 1.6 26 1340 300 30 * 6.4 1.6 24 1290 300 38 7/2.6 7.8 1.8 29 1690 300 38 * 7.3 1.8 28 1630 300 50 19/1.8 9.0 1.8 31 2090 300 50 * 8.4 1.8 30 2010 300 60 19/2.0 10.0 1.8 34 2480 300 60 * 9.3 1.8 33 2370 300 80 19/2.3 11.5 2.0 38 3250 300 80 * 10.7 2.0 36 3120 300 100 19/2.6 13.0 2.0 42 3990 300 100 * 12.0 2.0 40 3780 300 125 19/2.9 14.5 2.2 46 4910 300 125 * 13.5 2.2 44 4720 300 150 37/2.3 16.1 2.2 50 5810 300 150 * 14.7 2.2 47 5520 300 200 37/2.6 18.2 2.4 56 7330 200 200 * 17.0 2.4 53 7260 200 250 61/2.3 20.7 2.4 62 9300 200 250 * 19.0 2.4 58 8980 200 325 61/2.6 23.4 2.6 69 11780 150 325 * 21.7 2.6 65 11530 150 *Compacted stranded conductor 600V FOUR-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 9.8 125 300 - 1/1.2 1.2 0.8 10.5 145 200 - 1/1.6 1.6 0.8 11.5 190 200 - 1/2.0 2.0 0.8 12.5 250 150 - 1/2.6 2.6 1.0 15.0 385 300 - 1/3.2 3.2 1.2 17.0 550 300 2.0 7/0.6 1.8 0.8 12.0 200 200 3.5 7/0.8 2.4 0.8 13.5 290 150 5.5 7/1.0 3.0 1.0 16.0 420 300 8 7/1.2 3.6 1.2 18.0 590 300 8 * 3.4 1.2 17.5 550 300 14 7/1.6 4.8 1.4 22 945 300 14 * 4.4 1.4 21 875 300 22 7/2.0 6.0 1.6 27 1390 300 22 * 5.5 1.6 25 1290 300 30 7/2.3 6.9 1.6 29 1720 300 30 * 6.4 1.6 27 1650 300 38 7/2.6 7.8 1.8 32 2180 300 38 * 7.3 1.8 31 2100 300 50 19/1.8 9.0 1.8 35 2690 300 50 * 8.4 1.8 33 2600 300 60 19/2.0 10.0 1.8 38 3210 300 60 * 9.3 1.8 36 3090 300 80 19/2.3 11.5 2.0 42 4200 300 80 * 10.7 2.0 40 4070 300 100 19/2.6 13.0 2.0 47 5200 300 100 * 12.0 2.0 44 4950 300 125 19/2.9 14.5 2.2 51 6380 300 125 * 13.5 2.2 49 6150 300 150 37/2.3 16.1 2.2 56 7550 300 150 * 14.7 2.2 52 7210 300 200 37/2.6 18.2 2.4 62 9590 200 200 * 17.0 2.4 59 9480 200 250 61/2.3 20.7 2.4 69 12200 200 250 * 19.0 2.4 65 11750 200 325 61/2.6 23.4 2.6 77 15240 150 325 * 21.7 2.6 73 15100 150 *Compacted stranded conductorLP
600V Grade EPR (Ethylene Propylene Rubber) Insulated Lead Wires for Electric Machinery and Apparatus. The Ethylene Polyethylene insulated lead wires (LP) shall comply with the standard of CNS 5747. Features Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: EPR Introduction: The Ethylene Polyethylene Rubber (EPR) insulated lead wire has excellent flexibility. It can withstand impact, bending, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties. Specifications 600V ETHYLENE PROPYLENE RUBBER INSULATED LEAD WIRES Refer to CNS 5747 (LP) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 0.75 30/0.18 1.1 0.8 3.4 15 200 1.25 50/0.18 1.5 0.8 3.8 21 200 2.0 37/0.26 1.8 0.8 4.1 28 200 3.5 45/0.32 2.5 1.1 4.8 47 200 5.5 35/0.45 3.1 1.1 5.8 70 200 8 80/0.45 3.7 1.1 6.4 95 200 14 88/0.45 4.9 1.1 7.6 155 200 22 7/20/0.45 7.0 1.4 10.2 250 200 30 7/27/0.45 8.1 1.4 11.4 320 100 38 7/34/0.45 9.1 1.4 12.4 405 100 50 19/16/0.45 10.4 1.8 14.3 525 300 60 19/20/0.45 11.6 1.8 15.6 640 300 80 19/27/0.45 13.5 1.8 17.5 845 300 100 19/34/0.45 15.2 2.3 20.3 1100 300 125 19/42/0.45 16.8 2.3 21.9 1330 300 150 27/34/0.45 18.7 2.3 23.9 1520 300 200 37/34/0.45 21.2 2.9 27.5 2090 200 250 37/42/0.45 23.6 2.9 29.9 2540 200 325 37/55/0.45 27.0 2.9 33.4 3310 150LHH
600V Grade Hypalon Rubber Insulated Lead Wires for Electric Machinery and Apparatus. The Chlorosulfonated Polyethylene insulated lead wires (LHH) shall comply with the standard of CNS 5747. Features Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: Hypalon Introduction:The Chlorosulfonated Polyethylene (HYPALON) insulated lead wire has excellent flexibility. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties. Specifications 600V Chlorosulhponated Polyethylene Rubber(HYPALON)Insulated Lead Wires Refer to CNS 5747 (LHH) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 3.5 45/0.32 2.5 1.1 5.4 55 200 5.5 35/0.45 3.1 1.1 6.0 75 200 8 80/0.45 3.7 1.1 6.6 100 200 14 88/0.45 4.9 1.1 7.8 170 200 22 7/20/0.45 7.0 1.4 10.7 275 200 30 7/27/0.45 8.1 1.4 11.8 360 100 38 7/34/0.45 9.1 1.4 12.8 450 100 50 19/16/0.45 10.4 1.8 15.0 570 300 60 19/20/0.45 11.6 1.8 16.2 695 300 80 19/27/0.45 13.5 1.8 18.1 915 300 100 19/34/0.45 15.2 2.3 20.9 1180 300 125 19/42/0.45 16.8 2.3 22.5 1421 300 150 27/34/0.45 18.7 2.3 24.4 1623 500 200 37/34/0.45 21.2 2.9 28.2 2231 500 250 37/42/0.45 23.6 2.9 30.6 2704 500 325 37/55/0.45 27.0 2.9 34.1 3403 500IV
600V Polyvinyl chloride insulated wires (Code designation: IV). It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 679. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated wire has labeled our National Quality Standard. Specifications 600V Single Core PVC Insulated Wire (IV) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/0.8 0.8 0.8 2.4 11 300 - 1/1.0 1.0 0.8 2.6 14 300 - 1/1.2 1.2 0.8 2.8 17 300 - 1/1.6 1.6 0.8 3.2 27 300 - 1/2.0 2.0 0.8 3.6 38 300 - 1/2.6 2.6 1.0 4.6 65 300 - 1/3.2 3.2 1.2 5.6 95 300 0.9 7/0.4 1.2 0.8 2.8 16 300 1.25 7/0.45 1.35 0.8 3.0 19 300 2.0 7/0.6 1.8 0.8 3.4 28 300 3.5 7/0.8 2.4 0.8 4.0 45 300 5.5 7/1.0 3.0 1.0 5.0 70 300 8 7/1.2 3.6 1.2 6.0 105 300 8 * 3.4 1.2 5.8 100 300 14 7/1.6 4.8 1.4 7.6 175 300 14 * 4.4 1.4 7.2 160 300 22 7/2.0 6.0 1.6 9.2 265 300 22 * 5.5 1.6 8.7 245 300 30 7/2.3 6.9 1.6 10.5 335 300 30 * 6.4 1.6 10.0 325 300 38 7/2.6 7.8 1.8 11.5 430 300 38 * 7.3 1.8 11.0 405 300 50 19/1.8 9.0 1.8 13.0 535 300 50 * 8.4 1.8 12.4 525 300 60 19/2.0 10.0 1.8 14 650 300 60 * 9.3 1.8 13.3 630 300 80 19/2.3 11.5 2.0 15.5 850 300 80 * 10.7 2.0 14.7 815 300 100 19/2.6 13.0 2.0 17.0 1080 300 100 * 12.0 2.0 16.0 1025 300 125 19/2.9 14.5 2.2 19.0 1300 300 125 * 13.5 2.2 18.0 1275 300 150 37/2.3 16.1 2.2 21 1610 300 150 * 14.7 2.2 20 1575 300 200 37/2.6 18.2 2.4 23 2040 300 200 * 17.0 2.4 22 1965 300 250 61/2.3 20.7 2.4 26 2610 200 250 * 19.0 2.4 24 2495 200 325 61/2.6 23.4 2.6 29 3320 200 325 * 21.7 2.6 27 3170 200 400 61/2.9 26.1 2.6 32 4080 200 400 * 24.1 2.6 30 3940 200 500 61/3.2 28.8 2.8 35 4970 200 500 * 25.9 2.8 33 4770 200 * Compacted stranded conductorHR-CV
600V Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Jacketed Control Cables. It is used at wiring for control circuit of fire-fighting equipment. The control cables shall comply with the standard of CNS 11175. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Insulation: XLPE. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction: 600V Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Jacketed Cables (HR-CV). The product is passed with the test of 310℃×15min (CNS 11175). The quality of HR_CV is approved by National Fire Agency, Ministry of the Interior. Specifications 600V, XLPE Insulation, PVC(PE) Sheath Heat-Resistance Wire with Circular Type. 1~3 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 1 1.25 7/0.45 1.35 0.8 1.0 5.0 300 2.0 7/0.6 1.8 0.8 1.0 5.4 300 3.5 7/0.8 2.4 0.8 1.0 6.0 300 5.5 7/1.0 3.0 1.0 1.0 7.0 300 8 7/1.2 3.6 1.0 1.0 7.6 300 8 *CCC 3.4 1.0 1.0 7.4 300 14 7/1.6 4.8 1.0 1.1 9.0 300 14 *CCC 4.4 1.0 1.1 8.6 300 22 7/2.0 6.0 1.2 1.1 10.6 300 22 *CCC 5.5 1.2 1.1 10.1 300 2 1.25 7/0.45 1.35 0.8 1.2 8.6 300 2.0 7/0.6 1.8 0.8 1.2 9.5 300 3.5 7/0.8 2.4 0.8 1.2 10.7 300 5.5 7/1.0 3.0 1.0 1.2 12.7 300 8 7/1.2 3.6 1.0 1.0 13.9 300 8 *CCC 3.4 1.0 1.0 13.5 300 14 7/1.6 4.8 1.0 1.1 16.5 300 14 *CCC 4.4 1.0 1.1 15.7 300 22 7/2.0 6.0 1.2 1.1 20.1 300 22 *CCC 5.5 1.2 1.1 18.9 300 3 1.25 7/0.45 1.35 0.8 1.0 9.1 300 2.0 7/0.6 1.8 0.8 1.0 10.0 300 3.5 7/0.8 2.4 0.8 1.0 11.3 300 5.5 7/1.0 3.0 1.0 1.0 13.5 300 8 7/1.2 3.6 1.0 1.0 15.0 300 8 *CCC 3.4 1.0 1.0 14.5 300 14 7/1.6 4.8 1.0 1.1 18.7 300 14 *CCC 4.4 1.0 1.1 16.9 300 22 7/2.0 6.0 1.2 1.1 21.4 300 22 *CCC 5.5 1.2 1.1 20.3 300 *CCC ( Circular Compacted Conductor) 600V, XLPE Insulation, PVC (PE) Sheath Heat-Resistance Wire with Circular Type. 4~7 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 4 1.25 7/0.45 1.35 0.8 1.2 9.8 300 2.0 7/0.6 1.8 0.8 1.2 10.9 300 3.5 7/0.8 2.4 0.8 1.2 12.4 300 5.5 7/1.0 3.0 1.0 1.3 15.0 300 8 7/1.2 3.6 1.0 1.3 16.4 300 8 *CCC 3.4 1.0 1.3 15.9 300 14 7/1.6 4.8 1.0 1.5 19.7 300 14 *CCC 4.4 1.0 1.4 18.5 300 22 7/2.0 6.0 1.2 1.6 23.8 300 22 *CCC 5.5 1.2 1.6 22.6 300 5 1.25 7/0.45 1.35 0.8 1.2 10.7 300 2.0 7/0.6 1.8 0.8 1.2 11.9 300 3.5 7/0.8 2.4 0.8 1.2 13.5 300 5.5 7/1.0 3.0 1.0 1.3 16.4 300 8 7/1.2 3.6 1.0 1.4 18.2 300 8 *CCC 3.4 1.0 1.4 17.7 300 14 7/1.6 4.8 1.0 1.5 21.7 300 14 *CCC 4.4 1.0 1.5 20.6 300 6 1.25 7/0.45 1.35 0.8 1.2 11.6 300 2.0 7/0.6 1.8 0.8 1.2 12.9 300 3.5 7/0.8 2.4 0.8 1.3 14.9 300 5.5 7/1.0 3.0 1.0 1.4 18.1 300 8 7/1.2 3.6 1.0 1.5 20.1 300 8 *CCC 3.4 1.0 1.4 19.3 300 14 7/1.6 4.8 1.0 1.6 23.9 300 14 *CCC 4.4 1.0 1.6 22.7 300 7 1.25 7/0.45 1.35 0.8 1.2 11.6 300 2.0 7/0.6 1.8 0.8 1.2 12.9 300 3.5 7/0.8 2.4 0.8 1.3 14.9 300 5.5 7/1.0 3.0 1.0 1.4 18.1 300 8 7/1.2 3.6 1.0 1.5 20.1 300 8 *CCC 3.4 1.0 1.4 19.3 300 *CCC ( Circular Compacted Conductor) 600V, XLPE Insulation, PVC (PE) Sheath Heat-Resistance Wire with Circular Type. 8~30 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 1.25 7/0.45 1.35 0.8 1.2 12.4 300 2.0 7/0.6 1.8 0.8 1.2 13.9 300 3.5 7/0.8 2.4 0.8 1.3 16.1 300 5.5 7/1.0 3.0 1.0 1.5 19.8 300 8 7/1.2 3.6 1.0 1.5 21.8 300 8 *CCC 3.4 1.0 1.5 21.1 300 10 1.25 7/0.45 1.35 0.8 1.3 14.7 300 2.0 7/0.6 1.8 0.8 1.3 16.5 300 3.5 7/0.8 2.4 0.8 1.4 19.1 300 5.5 7/1.0 3.0 1.0 1.6 23.5 300 8 7/1.2 3.6 1.0 1.7 26.1 300 8 *CCC 3.4 1.0 1.7 25.3 300 12 1.25 7/0.45 1.35 0.8 1.3 15.2 300 2.0 7/0.6 1.8 0.8 1.4 17.2 300 3.5 7/0.8 2.4 0.8 1.5 19.9 300 5.5 7/1.0 3.0 1.0 1.6 24.3 300 8 7/1.2 3.6 1.0 1.7 27.0 300 8 *CCC 3.4 1.0 1.7 26.1 300 15 1.25 7/0.45 1.35 0.8 1.3 16.3 300 2.0 7/0.6 1.8 0.8 1.4 18.6 300 3.5 7/0.8 2.4 0.8 1.5 21.5 300 5.5 7/1.0 3.0 1.0 1.7 26.4 300 20 1.25 7/0.45 1.35 0.8 1.4 18.4 300 2.0 7/0.6 1.8 0.8 1.5 20.9 300 3.5 7/0.8 2.4 0.8 1.6 24.2 300 5.5 7/1.0 3.0 1.0 1.8 29.8 300 30 1.25 7/0.45 1.35 0.8 1.6 22.4 300 2.0 7/0.6 1.8 0.8 1.7 25.5 300 3.5 7/0.8 2.4 0.8 1.8 29.6 300 *CCC ( Circular Compacted Conductor)HIV
600V Heat-Resistance Polyvinyl chloride insulated wires (Code designation: HIV). It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 8379. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated wire has heat-resistance properties. Sepcifications 600V GRADE HEAT-RESISTANCE PVC INSULATED WIRES (HIV) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.2 1.2 0.8 2.8 17 300 - 1/1.6 1.6 0.8 3.2 27 300 - 1/2.0 2.0 0.8 3.6 38 300 - 1/2.6 2.6 1.0 4.6 65 300 - 1/3.2 3.2 1.2 6.6 95 300 0.9 7/0.4 1.2 0.8 2.8 16 300 1.25 7/0.45 1.4 0.8 3.0 19 300 2.0 7/0.6 1.8 0.8 3.4 28 300 3.5 7/0.8 2.4 0.8 4.0 45 300 5.5 7/1.0 3.0 1.0 5.0 70 300 8 7/1.2 3.6 1.2 6.0 105 300 14 7/1.6 4.8 1.4 7.6 170 300 22 7/2.0 6.0 1.6 9.2 260 200 38 7/2.6 7.8 1.8 11.5 430 100 60 19/2.0 10.0 1.8 14 650 300 100 19/2.6 13.0 2.0 17.0 1070 300 150 37/2.3 16.1 2.2 21 1600 300 200 37/2.6 18.2 2.4 23 2020 300 250 61/2.3 20.7 2.4 26 2580 200 325 61/2.6 23.4 2.6 29 3280 200 400 61/2.9 26.1 2.6 32 4040 200 500 61/3.2 28.8 2.8 35 4910 200