Products
LP
600V Grade EPR (Ethylene Propylene Rubber) Insulated Lead Wires for Electric Machinery and Apparatus. The Ethylene Polyethylene insulated lead wires (LP) shall comply with the standard of CNS 5747.
Features
Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: EPR Introduction: The Ethylene Polyethylene Rubber (EPR) insulated lead wire has excellent flexibility. It can withstand impact, bending, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties.
Specifications
600V ETHYLENE PROPYLENE RUBBER INSULATED LEAD WIRES Refer to CNS 5747 (LP)
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
---|---|---|---|---|---|---|
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
0.75 | 30/0.18 | 1.1 | 0.8 | 3.4 | 15 | 200 |
1.25 | 50/0.18 | 1.5 | 0.8 | 3.8 | 21 | 200 |
2.0 | 37/0.26 | 1.8 | 0.8 | 4.1 | 28 | 200 |
3.5 | 45/0.32 | 2.5 | 1.1 | 4.8 | 47 | 200 |
5.5 | 35/0.45 | 3.1 | 1.1 | 5.8 | 70 | 200 |
8 | 80/0.45 | 3.7 | 1.1 | 6.4 | 95 | 200 |
14 | 88/0.45 | 4.9 | 1.1 | 7.6 | 155 | 200 |
22 | 7/20/0.45 | 7.0 | 1.4 | 10.2 | 250 | 200 |
30 | 7/27/0.45 | 8.1 | 1.4 | 11.4 | 320 | 100 |
38 | 7/34/0.45 | 9.1 | 1.4 | 12.4 | 405 | 100 |
50 | 19/16/0.45 | 10.4 | 1.8 | 14.3 | 525 | 300 |
60 | 19/20/0.45 | 11.6 | 1.8 | 15.6 | 640 | 300 |
80 | 19/27/0.45 | 13.5 | 1.8 | 17.5 | 845 | 300 |
100 | 19/34/0.45 | 15.2 | 2.3 | 20.3 | 1100 | 300 |
125 | 19/42/0.45 | 16.8 | 2.3 | 21.9 | 1330 | 300 |
150 | 27/34/0.45 | 18.7 | 2.3 | 23.9 | 1520 | 300 |
200 | 37/34/0.45 | 21.2 | 2.9 | 27.5 | 2090 | 200 |
250 | 37/42/0.45 | 23.6 | 2.9 | 29.9 | 2540 | 200 |
325 | 37/55/0.45 | 27.0 | 2.9 | 33.4 | 3310 | 150 |
更多商品
LHH
600V Grade Hypalon Rubber Insulated Lead Wires for Electric Machinery and Apparatus. The Chlorosulfonated Polyethylene insulated lead wires (LHH) shall comply with the standard of CNS 5747. Features Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: Hypalon Introduction:The Chlorosulfonated Polyethylene (HYPALON) insulated lead wire has excellent flexibility. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties. Specifications 600V Chlorosulhponated Polyethylene Rubber(HYPALON)Insulated Lead Wires Refer to CNS 5747 (LHH) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 3.5 45/0.32 2.5 1.1 5.4 55 200 5.5 35/0.45 3.1 1.1 6.0 75 200 8 80/0.45 3.7 1.1 6.6 100 200 14 88/0.45 4.9 1.1 7.8 170 200 22 7/20/0.45 7.0 1.4 10.7 275 200 30 7/27/0.45 8.1 1.4 11.8 360 100 38 7/34/0.45 9.1 1.4 12.8 450 100 50 19/16/0.45 10.4 1.8 15.0 570 300 60 19/20/0.45 11.6 1.8 16.2 695 300 80 19/27/0.45 13.5 1.8 18.1 915 300 100 19/34/0.45 15.2 2.3 20.9 1180 300 125 19/42/0.45 16.8 2.3 22.5 1421 300 150 27/34/0.45 18.7 2.3 24.4 1623 500 200 37/34/0.45 21.2 2.9 28.2 2231 500 250 37/42/0.45 23.6 2.9 30.6 2704 500 325 37/55/0.45 27.0 2.9 34.1 3403 500IV
600V Polyvinyl chloride insulated wires (Code designation: IV). It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 679. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated wire has labeled our National Quality Standard. Specifications 600V Single Core PVC Insulated Wire (IV) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/0.8 0.8 0.8 2.4 11 300 - 1/1.0 1.0 0.8 2.6 14 300 - 1/1.2 1.2 0.8 2.8 17 300 - 1/1.6 1.6 0.8 3.2 27 300 - 1/2.0 2.0 0.8 3.6 38 300 - 1/2.6 2.6 1.0 4.6 65 300 - 1/3.2 3.2 1.2 5.6 95 300 0.9 7/0.4 1.2 0.8 2.8 16 300 1.25 7/0.45 1.35 0.8 3.0 19 300 2.0 7/0.6 1.8 0.8 3.4 28 300 3.5 7/0.8 2.4 0.8 4.0 45 300 5.5 7/1.0 3.0 1.0 5.0 70 300 8 7/1.2 3.6 1.2 6.0 105 300 8 * 3.4 1.2 5.8 100 300 14 7/1.6 4.8 1.4 7.6 175 300 14 * 4.4 1.4 7.2 160 300 22 7/2.0 6.0 1.6 9.2 265 300 22 * 5.5 1.6 8.7 245 300 30 7/2.3 6.9 1.6 10.5 335 300 30 * 6.4 1.6 10.0 325 300 38 7/2.6 7.8 1.8 11.5 430 300 38 * 7.3 1.8 11.0 405 300 50 19/1.8 9.0 1.8 13.0 535 300 50 * 8.4 1.8 12.4 525 300 60 19/2.0 10.0 1.8 14 650 300 60 * 9.3 1.8 13.3 630 300 80 19/2.3 11.5 2.0 15.5 850 300 80 * 10.7 2.0 14.7 815 300 100 19/2.6 13.0 2.0 17.0 1080 300 100 * 12.0 2.0 16.0 1025 300 125 19/2.9 14.5 2.2 19.0 1300 300 125 * 13.5 2.2 18.0 1275 300 150 37/2.3 16.1 2.2 21 1610 300 150 * 14.7 2.2 20 1575 300 200 37/2.6 18.2 2.4 23 2040 300 200 * 17.0 2.4 22 1965 300 250 61/2.3 20.7 2.4 26 2610 200 250 * 19.0 2.4 24 2495 200 325 61/2.6 23.4 2.6 29 3320 200 325 * 21.7 2.6 27 3170 200 400 61/2.9 26.1 2.6 32 4080 200 400 * 24.1 2.6 30 3940 200 500 61/3.2 28.8 2.8 35 4970 200 500 * 25.9 2.8 33 4770 200 * Compacted stranded conductorHR-CV
600V Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Jacketed Control Cables. It is used at wiring for control circuit of fire-fighting equipment. The control cables shall comply with the standard of CNS 11175. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Insulation: XLPE. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction: 600V Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Jacketed Cables (HR-CV). The product is passed with the test of 310℃×15min (CNS 11175). The quality of HR_CV is approved by National Fire Agency, Ministry of the Interior. Specifications 600V, XLPE Insulation, PVC(PE) Sheath Heat-Resistance Wire with Circular Type. 1~3 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 1 1.25 7/0.45 1.35 0.8 1.0 5.0 300 2.0 7/0.6 1.8 0.8 1.0 5.4 300 3.5 7/0.8 2.4 0.8 1.0 6.0 300 5.5 7/1.0 3.0 1.0 1.0 7.0 300 8 7/1.2 3.6 1.0 1.0 7.6 300 8 *CCC 3.4 1.0 1.0 7.4 300 14 7/1.6 4.8 1.0 1.1 9.0 300 14 *CCC 4.4 1.0 1.1 8.6 300 22 7/2.0 6.0 1.2 1.1 10.6 300 22 *CCC 5.5 1.2 1.1 10.1 300 2 1.25 7/0.45 1.35 0.8 1.2 8.6 300 2.0 7/0.6 1.8 0.8 1.2 9.5 300 3.5 7/0.8 2.4 0.8 1.2 10.7 300 5.5 7/1.0 3.0 1.0 1.2 12.7 300 8 7/1.2 3.6 1.0 1.0 13.9 300 8 *CCC 3.4 1.0 1.0 13.5 300 14 7/1.6 4.8 1.0 1.1 16.5 300 14 *CCC 4.4 1.0 1.1 15.7 300 22 7/2.0 6.0 1.2 1.1 20.1 300 22 *CCC 5.5 1.2 1.1 18.9 300 3 1.25 7/0.45 1.35 0.8 1.0 9.1 300 2.0 7/0.6 1.8 0.8 1.0 10.0 300 3.5 7/0.8 2.4 0.8 1.0 11.3 300 5.5 7/1.0 3.0 1.0 1.0 13.5 300 8 7/1.2 3.6 1.0 1.0 15.0 300 8 *CCC 3.4 1.0 1.0 14.5 300 14 7/1.6 4.8 1.0 1.1 18.7 300 14 *CCC 4.4 1.0 1.1 16.9 300 22 7/2.0 6.0 1.2 1.1 21.4 300 22 *CCC 5.5 1.2 1.1 20.3 300 *CCC ( Circular Compacted Conductor) 600V, XLPE Insulation, PVC (PE) Sheath Heat-Resistance Wire with Circular Type. 4~7 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 4 1.25 7/0.45 1.35 0.8 1.2 9.8 300 2.0 7/0.6 1.8 0.8 1.2 10.9 300 3.5 7/0.8 2.4 0.8 1.2 12.4 300 5.5 7/1.0 3.0 1.0 1.3 15.0 300 8 7/1.2 3.6 1.0 1.3 16.4 300 8 *CCC 3.4 1.0 1.3 15.9 300 14 7/1.6 4.8 1.0 1.5 19.7 300 14 *CCC 4.4 1.0 1.4 18.5 300 22 7/2.0 6.0 1.2 1.6 23.8 300 22 *CCC 5.5 1.2 1.6 22.6 300 5 1.25 7/0.45 1.35 0.8 1.2 10.7 300 2.0 7/0.6 1.8 0.8 1.2 11.9 300 3.5 7/0.8 2.4 0.8 1.2 13.5 300 5.5 7/1.0 3.0 1.0 1.3 16.4 300 8 7/1.2 3.6 1.0 1.4 18.2 300 8 *CCC 3.4 1.0 1.4 17.7 300 14 7/1.6 4.8 1.0 1.5 21.7 300 14 *CCC 4.4 1.0 1.5 20.6 300 6 1.25 7/0.45 1.35 0.8 1.2 11.6 300 2.0 7/0.6 1.8 0.8 1.2 12.9 300 3.5 7/0.8 2.4 0.8 1.3 14.9 300 5.5 7/1.0 3.0 1.0 1.4 18.1 300 8 7/1.2 3.6 1.0 1.5 20.1 300 8 *CCC 3.4 1.0 1.4 19.3 300 14 7/1.6 4.8 1.0 1.6 23.9 300 14 *CCC 4.4 1.0 1.6 22.7 300 7 1.25 7/0.45 1.35 0.8 1.2 11.6 300 2.0 7/0.6 1.8 0.8 1.2 12.9 300 3.5 7/0.8 2.4 0.8 1.3 14.9 300 5.5 7/1.0 3.0 1.0 1.4 18.1 300 8 7/1.2 3.6 1.0 1.5 20.1 300 8 *CCC 3.4 1.0 1.4 19.3 300 *CCC ( Circular Compacted Conductor) 600V, XLPE Insulation, PVC (PE) Sheath Heat-Resistance Wire with Circular Type. 8~30 Cores (HR-CV) Conductor Nominal insulation Thickness mm Nominal Thickness of Sheath mm Approx. Overall Diameter mm Standard Length M CoreNo. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 1.25 7/0.45 1.35 0.8 1.2 12.4 300 2.0 7/0.6 1.8 0.8 1.2 13.9 300 3.5 7/0.8 2.4 0.8 1.3 16.1 300 5.5 7/1.0 3.0 1.0 1.5 19.8 300 8 7/1.2 3.6 1.0 1.5 21.8 300 8 *CCC 3.4 1.0 1.5 21.1 300 10 1.25 7/0.45 1.35 0.8 1.3 14.7 300 2.0 7/0.6 1.8 0.8 1.3 16.5 300 3.5 7/0.8 2.4 0.8 1.4 19.1 300 5.5 7/1.0 3.0 1.0 1.6 23.5 300 8 7/1.2 3.6 1.0 1.7 26.1 300 8 *CCC 3.4 1.0 1.7 25.3 300 12 1.25 7/0.45 1.35 0.8 1.3 15.2 300 2.0 7/0.6 1.8 0.8 1.4 17.2 300 3.5 7/0.8 2.4 0.8 1.5 19.9 300 5.5 7/1.0 3.0 1.0 1.6 24.3 300 8 7/1.2 3.6 1.0 1.7 27.0 300 8 *CCC 3.4 1.0 1.7 26.1 300 15 1.25 7/0.45 1.35 0.8 1.3 16.3 300 2.0 7/0.6 1.8 0.8 1.4 18.6 300 3.5 7/0.8 2.4 0.8 1.5 21.5 300 5.5 7/1.0 3.0 1.0 1.7 26.4 300 20 1.25 7/0.45 1.35 0.8 1.4 18.4 300 2.0 7/0.6 1.8 0.8 1.5 20.9 300 3.5 7/0.8 2.4 0.8 1.6 24.2 300 5.5 7/1.0 3.0 1.0 1.8 29.8 300 30 1.25 7/0.45 1.35 0.8 1.6 22.4 300 2.0 7/0.6 1.8 0.8 1.7 25.5 300 3.5 7/0.8 2.4 0.8 1.8 29.6 300 *CCC ( Circular Compacted Conductor)HIV
600V Heat-Resistance Polyvinyl chloride insulated wires (Code designation: HIV). It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 8379. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated wire has heat-resistance properties. Sepcifications 600V GRADE HEAT-RESISTANCE PVC INSULATED WIRES (HIV) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.2 1.2 0.8 2.8 17 300 - 1/1.6 1.6 0.8 3.2 27 300 - 1/2.0 2.0 0.8 3.6 38 300 - 1/2.6 2.6 1.0 4.6 65 300 - 1/3.2 3.2 1.2 6.6 95 300 0.9 7/0.4 1.2 0.8 2.8 16 300 1.25 7/0.45 1.4 0.8 3.0 19 300 2.0 7/0.6 1.8 0.8 3.4 28 300 3.5 7/0.8 2.4 0.8 4.0 45 300 5.5 7/1.0 3.0 1.0 5.0 70 300 8 7/1.2 3.6 1.2 6.0 105 300 14 7/1.6 4.8 1.4 7.6 170 300 22 7/2.0 6.0 1.6 9.2 260 200 38 7/2.6 7.8 1.8 11.5 430 100 60 19/2.0 10.0 1.8 14 650 300 100 19/2.6 13.0 2.0 17.0 1070 300 150 37/2.3 16.1 2.2 21 1600 300 200 37/2.6 18.2 2.4 23 2020 300 250 61/2.3 20.7 2.4 26 2580 200 325 61/2.6 23.4 2.6 29 3280 200 400 61/2.9 26.1 2.6 32 4040 200 500 61/3.2 28.8 2.8 35 4910 200FR-CV
600V Mica layer, Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Jacketed Cables. It is used at wiring for emergency power and fire-fighting equipment. The cables shall comply with the standard of CNS 11359. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Mica tape (3) Insulation: XLPE. (4) Two or more cores are twisted together,cable core covered with proper separator (5) Sheath: PVC Introduction: 600V Mica layer, Cross-Linked Polyethylene (XLPE) Insulated and Polyvinyl Chloride (PVC) Jacketed Cables (FR-CV). The product is passed with the fire-resistance test of 750℃×90min (IEC 60331) or the test of 840℃×30min (CNS 11174). The quality of FR_CV is approved by National Fire Agency, Ministry of the Interior. 600V FR-CV power cable has labeled our National Quality Standard. Specifications 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. Single Core (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 2.0 7/0.6 1.8 0.4 0.8 7.2 300 3.5 7/0.8 2.4 0.4 0.8 7.8 300 5.5 7/1.0 3.0 0.4 1.0 8.8 300 8 7/1.2 3.6 0.4 1.0 9.4 300 8 *CCC 3.4 0.4 1.0 9.2 300 14 7/1.6 4.8 0.6 1.0 11.0 300 14 *CCC 4.4 0.6 1.0 10.5 300 22 7/2.0 6.0 0.6 1.2 12.5 300 22 *CCC 5.5 0.6 1.2 12.0 300 30 7/2.3 6.9 0.6 1.2 13.5 300 30 *CCC 6.5 0.6 1.2 13.0 300 38 7/2.6 7.8 0.6 1.2 14.5 300 38 *CCC 7.3 0.6 1.2 14.0 300 50 19/1.8 9.0 0.6 1.5 16.5 300 50 *CCC 8.5 0.6 1.5 16.0 300 60 19/2.0 10.0 0.6 1.5 17.0 300 60 *CCC 9.3 0.6 1.5 16.5 300 80 19/2.3 11.5 0.6 1.5 19.0 300 80 *CCC 10.8 0.6 1.5 18.0 300 100 19/2.6 13.0 0.6 2.0 21.0 300 100 *CCC 12.0 0.6 2.0 20.0 300 125 19/2.9 14.5 0.6 2.0 23.0 300 125 *CCC 13.5 0.6 2.0 22.0 300 150 37/2.3 16.1 0.6 2.0 25.0 300 150 *CCC 14.7 0.6 2.0 23.0 300 200 37/2.6 18.2 0.6 2.5 28.0 200 200 *CCC 17.0 0.6 2.5 27.0 200 250 61/2.3 20.7 0.6 2.5 31.0 200 250 *CCC 19.0 0.6 2.5 29.0 200 325 61/2.6 23.4 0.6 2.5 33.5 200 325 *CCC 21.7 0.6 2.5 32.0 200 400 61/2.9 26.1 0.6 2.5 36.5 150 400 *CCC 24.1 0.6 2.5 34.5 150 500 61/2.9 26.1 0.6 2.5 40.0 150 500 *CCC 26.9 0.6 3.0 38.5 150 600 91/2.9 31.9 0.6 3.0 44.0 150 600 *CCC 29.5 0.6 3.0 41.5 150 800 127/2.8 36.4 0.6 3.5 50.0 150 800 *CCC 34.0 0.6 3.5 48.0 150 1000 127/3.2 41.6 0.6 3.5 56.0 150 1000 *CCC 38 0.6 3.5 52.0 150 *CCC( Circular Compacted Conductor) 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. 2 Cores (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 1.25 7/0.45 1.35 0.4 0.8 11.0 300 2.0 7/0.6 1.8 0.4 0.8 12.0 300 3.5 7/0.8 2.4 0.4 0.8 13.0 300 5.5 7/1.0 3.0 0.4 1.0 15.0 300 8 7/1.2 3.6 0.4 1.0 16.0 300 8 *CCC 3.4 0.4 1.0 16.0 300 14 7/1.6 4.8 0.6 1.0 19.0 300 14 *CCC 4.4 0.6 1.0 18.5 300 22 7/2.0 6.0 0.6 1.2 22.5 300 22 *CCC 5.5 0.6 1.2 21.5 300 30 7/2.3 6.9 0.6 1.2 24.0 300 30 *CCC 6.5 0.6 1.2 23.5 300 38 7/2.6 7.8 0.6 1.2 26.0 300 38 *CCC 7.3 0.6 1.2 25.0 300 50 19/1.8 9.0 0.6 1.5 30.0 300 50 *CCC 8.5 0.6 1.5 29.0 300 60 19/2.0 10.0 0.6 1.5 32.5 300 60 *CCC 9.3 0.6 1.5 31.0 300 80 19/2.3 11.5 0.6 1.5 35.5 300 80 *CCC 10.8 0.6 1.5 34.0 300 100 19/2.6 13.0 0.6 2.0 41.0 300 100 *CCC 12.0 0.6 2.0 39.0 300 125 19/2.9 14.5 0.6 2.0 44.5 300 125 *CCC 13.5 0.6 2.0 43.0 300 150 37/2.3 16.1 0.6 2.0 48.0 300 150 *CCC 14.7 0.6 2.0 45.0 300 200 37/2.6 18.2 0.6 2.5 56.0 200 200 *CCC 17.0 0.6 2.5 53.0 200 250 61/2.3 20.7 0.6 2.5 61.0 200 250 *CCC 19.0 0.6 2.5 57.0 200 325 61/2.6 23.4 0.6 2.5 67.0 200 325 *CCC 21.7 0.6 2.5 63.0 200 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. 3 Cores (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 1.25 7/0.45 1.35 0.4 0.8 12.0 300 2.0 7/0.6 1.8 0.4 0.8 13.0 300 3.5 7/0.8 2.4 0.4 0.8 14.0 300 5.5 7/1.0 3.0 0.4 1.0 16.0 300 8 7/1.2 3.6 0.4 1.0 17.5 300 8 *CCC 3.4 0.4 1.0 17.0 300 14 7/1.6 4.8 0.6 1.0 20.5 300 14 *CCC 4.4 0.6 1.0 19.5 300 22 7/2.0 6.0 0.6 1.2 24.0 300 22 *CCC 5.5 0.6 1.2 23.0 300 30 7/2.3 6.9 0.6 1.2 26 300 30 *CCC 6.5 0.6 1.2 25.5 300 38 7/2.6 7.8 0.6 1.2 28.5 300 38 *CCC 7.3 0.6 1.2 27.5 300 50 19/1.8 9.0 0.6 1.5 32.5 300 50 *CCC 8.5 0.6 1.5 31.5 300 60 19/2.0 10.0 0.6 1.5 35 300 60 *CCC 9.3 0.6 1.5 33.5 300 80 19/2.3 11.5 0.6 1.5 33.5 300 80 *CCC 10.8 0.6 1.5 37 300 100 19/2.6 13.0 0.6 2.0 44.5 300 100 *CCC 12.0 0.6 2.0 42 300 125 19/2.9 14.5 0.6 2.0 48 300 125 *CCC 13.5 0.6 2.0 46 300 150 37/2.3 16.1 0.6 2.0 51.5 300 150 *CCC 14.7 0.6 2.0 49 300 200 37/2.6 18.2 0.6 2.5 59 200 200 *CCC 17.0 0.6 2.5 57 200 250 61/2.3 20.7 0.6 2.5 65 200 250 *CCC 19.0 0.6 2.5 60.5 200 325 61/2.6 23.4 0.6 2.5 71 200 325 *CCC 21.7 0.6 2.5 67 200 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. 4 Cores (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 1.25 7/0.45 1.35 0.4 0.8 13.0 300 2.0 7/0.6 1.8 0.4 0.8 14.0 300 3.5 7/0.8 2.4 0.4 0.8 15.5 300 5.5 7/1.0 3.0 0.4 1.0 17.5 300 8 7/1.2 3.6 0.4 1.0 19.0 300 8 *CCC 3.4 0.4 1.0 18.5 300 14 7/1.6 4.8 0.6 1.0 23.0 300 14 *CCC 4.4 0.6 1.0 22.0 300 22 7/2.0 6.0 0.6 1.2 27.0 300 22 *CCC 5.5 0.6 1.2 25.5 300 30 7/2.3 6.9 0.6 1.2 29.0 300 30 *CCC 6.5 0.6 1.2 28.0 300 38 7/2.6 7.8 0.6 1.2 31.5 300 38 *CCC 7.3 0.6 1.2 30.5 300 50 19/1.8 9.0 0.6 1.5 36.0 300 50 *CCC 8.5 0.6 1.5 35.0 300 60 19/2.0 10.0 0.6 1.5 39.0 300 60 *CCC 9.3 0.6 1.5 37.0 300 80 19/2.3 11.5 0.6 1.5 42.5 300 80 *CCC 10.8 0.6 1.5 41.0 300 100 19/2.6 13.0 0.6 2.0 49.5 300 100 *CCC 12.0 0.6 2.0 47.0 300 125 19/2.9 14.5 0.6 2.0 53.0 300 125 *CCC 13.5 0.6 2.0 51.0 300 150 37/2.3 16.1 0.6 2.0 58.0 300 150 *CCC 14.7 0.6 2.0 54.0 300 200 37/2.6 18.2 0.6 2.5 66.0 200 200 *CCC 17.0 0.6 2.5 63.0 200 250 61/2.3 20.7 0.6 2.5 72.0 200 250 *CCC 19.0 0.6 2.5 68.0 200 325 61/2.6 23.4 0.6 2.5 79.0 200 325 *CCC 21.7 0.6 2.5 75.0 200 *CCC( Circular Compacted Conductor) 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. 5~10 Cores (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Core No. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 5 2.0 7/0.6 1.8 0.4 0.8 15.0 300 3.5 7/0.8 2.4 0.4 0.8 17.0 300 5.5 7/1.0 3.0 0.4 1.0 20.0 300 6 2.0 7/0.6 1.8 0.4 0.8 16.5 300 3.5 7/0.8 2.4 0.4 0.8 18.5 300 5.5 7/1.0 3.0 0.4 1.0 21.5 300 7 2.0 7/0.6 1.8 0.4 0.8 16.5 300 3.5 7/0.8 2.4 0.4 0.8 18.5 300 5.5 7/1.0 3.0 0.4 1.0 21.5 300 8 2.0 7/0.6 1.8 0.4 0.8 18.0 300 3.5 7/0.8 2.4 0.4 0.8 20.0 300 5.5 7/1.0 3.0 0.4 1.0 23.0 300 9 2.0 7/0.6 1.8 0.4 0.8 19.5 300 3.5 7/0.8 2.4 0.4 0.8 21.5 300 5.5 7/1.0 3.0 0.4 1.0 25.5 300 10 2.0 7/0.6 1.8 0.4 0.8 21.0 300 3.5 7/0.8 2.4 0.4 0.8 24.0 300 5.5 7/1.0 3.0 0.4 1.0 28.5 300 600V, XLPE (PE) Insulation, PVC (PE) Sheath Fire-Resistance Power Cable with Circular Type. 12~30 Cores (FR-CV) Conductor Thickness of Flame Resistance Layer mm Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Core No. C Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 12 2.0 7/0.6 1.8 0.4 0.8 22.0 300 3.5 7/0.8 2.4 0.4 0.8 25.0 300 5.5 7/1.0 3.0 0.4 1.0 29.5 300 16 2.0 7/0.6 1.8 0.4 0.8 25.0 300 3.5 7/0.8 2.4 0.4 0.8 28.0 300 5.5 7/1.0 3.0 0.4 1.0 33.0 300 19 2.0 7/0.6 1.8 0.4 0.8 26.0 300 3.5 7/0.8 2.4 0.4 0.8 29.0 300 5.5 7/1.0 3.0 0.4 1.0 35.0 300 24 2.0 7/0.6 1.8 0.4 0.8 31.0 300 3.5 7/0.8 2.4 0.4 0.8 35.0 300 27 2.0 7/0.6 1.8 0.4 0.8 32.0 300 3.5 7/0.8 2.4 0.4 0.8 36.0 300 30 2.0 7/0.6 1.8 0.4 0.8 33.0 300 3.5 7/0.8 2.4 0.4 0.8 37.0 300FR-CL
600V Mica layer, Cross-Linked Polyethylene Insulated, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables. It is used at wiring for emergency power and fire-fighting equipment. The cables shall comply with the standard of CNS 11359 . Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Mica tape (3) Insulation: XLPE. (4) Two or more cores are twisted together,cable core covered with proper separator (5) Sheath: LSHF Introduction: 600V Mica layer, Cross-Linked Polyethylene Insulated, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables (FR-CL). It has following characteristics: (1) Low toxicity index; per NES 713; toxicity index <=5 (2) Don’t produce halogen gas; per IEC 60754-1; Amount of HCL gas <=0.5% (3) Low smoke; LSHF compound per ASTM E662 smoke density test; Ds<=250,VOF4<=100 (4) Excellent flame resistance; per ASTM D2863 oxygen index; OI >=30; per IEEE 383 vertical open tray flame test; passed. The Low-Smoke and Halogen-Free (LSHF) wire and cable could minimize the lowest damage in case of fire. Therefore, the public areas, such as subway, tunnel, railway, public building, substreet, ships, power stations, school, hospital, and rapid transit system in more suitable to install the LSHF cable to secure the human lives and properties. Specifications 600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 1 - 1/1.0 1.0 0.8 6.4 55 - 1/1.2 1.2 0.8 6.6 60 - 1/1.6 1.6 0.8 7.0 70 - 1/2.0 2.0 0.8 7.4 85 - 1/2.6 2.6 1.0 8.4 120 0.9 7/0.4 1.2 0.8 6.7 55 1.25 7/0.45 1.35 0.8 6.8 60 2.0 7/0.6 1.8 0.8 7.2 75 3.5 7/0.8 2.4 0.8 7.8 93 5.5 7/1.0 3.0 1.0 8.8 125 8 * 3.4 1.0 9.2 146 14 * 4.4 1.0 10.5 211 22 * 5.5 1.2 12.0 313 30 * 6.5 1.2 13.0 406 38 * 7.3 1.2 14.0 479 50 * 8.5 1.5 16.0 609 60 * 9.3 1.5 16.5 703 80 * 10.8 1.5 18.0 897 100 * 12.0 2.0 20 1120 125 * 13.5 2.0 22 1430 150 * 14.7 2.0 23 1580 200 * 17.0 2.5 27 2190 250 * 19.0 2.5 29 2670 325 * 21.7 2.5 32 3390 400 * 24.1 2.5 34.5 4100 500 * 26.9 3.0 38.5 5180 * Compacted stranded conductor 600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 2 8 * 3.4 1.0 16.0 305 14 * 4.4 1.0 18.5 468 22 * 5.5 1.2 21.5 668 30 * 6.5 1.2 23.5 867 38 * 7.3 1.2 25.5 1080 50 * 8.5 1.5 29 1380 60 * 9.3 1.5 31 1610 80 * 10.8 1.5 34 2050 100 * 12.0 2.0 39 2610 125 * 13.5 2.0 43 3190 150 * 14.7 2.0 45 3700 200 * 17.0 2.5 53 4920 250 * 19.0 2.5 57 6000 325 * 21.7 2.5 63 7580 400 * 24.1 2.5 68 9170 500 * 26.9 3.0 76 11600 3 8 * 3.4 1.0 17.0 401 14 * 4.4 1.0 19.5 627 22 * 5.5 1.2 23 920 30 * 6.5 1.2 25.5 1220 38 * 7.3 1.2 27.5 1490 50 * 8.5 1.5 31.5 1910 60 * 9.3 1.5 33.5 2230 80 * 10.8 1.5 37 2860 100 * 12.0 2.0 42 3620 125 * 13.5 2.0 46 4480 150 * 14.7 2.0 49 5200 200 * 17.0 2.5 57 6800 250 * 19.0 2.5 60.5 8420 325 * 21.7 2.5 67 10700 400 * 24.1 2.5 74 12900 500 * 26.9 3.0 83 16400 * Compacted conductor 600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 4 - 1/1.0 1.0 0.8 12 150 - 1/1.2 1.2 0.8 12.5 170 - 1/1.6 1.6 0.8 13.5 218 - 1/2.0 2.0 0.8 14.5 274 - 1/2.6 2.6 1.0 16.5 396 0.9 7/0.4 1.2 0.8 12.2 156 1.25 7/0.45 1.35 0.8 13.0 176 2.0 7/0.6 1.8 0.8 14.0 222 3.5 7/0.8 2.4 0.8 15.5 301 5.5 7/1.0 3.0 1.0 17.5 421 8 * 3.4 1.0 18.5 505 14 * 4.4 1.0 22 800 22 * 5.5 1.2 25.5 1190 30 * 6.5 1.2 28 1640 38 * 7.3 1.2 30.5 1930 50 * 8.5 1.5 35 2480 60 * 9.3 1.5 37 2900 80 * 10.8 1.5 41 3740 100 * 12.0 2.0 47 4820 125 * 13.5 2.0 51 5820 150 * 14.7 2.0 54 6800 200 * 17.0 2.5 63 8990 250 * 19.0 2.5 68 11000 325 * 21.7 2.5 75 14000 400 * 24.1 2.5 82 17000 500 * 26.9 3.0 92 21600 * Compacted conductor 600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 5 - 1/1.0 1.0 0.8 13 175 - 1/1.2 1.2 0.8 13.5 200 - 1/1.6 1.6 0.8 14.5 250 - 1/2.0 2.0 0.8 15.5 330 - 1/2.6 2.6 1.0 18.5 430 0.9 7/0.4 1.2 0.8 13 160 1.25 7/0.45 1.35 0.8 14 207 2.0 7/0.6 1.8 0.8 15 260 3.5 7/0.8 2.4 0.8 17 360 5.5 7/1.0 3.0 1.0 20 510 8 * 3.4 1.0 21 613 14 * 4.4 1.0 24 955 22 * 5.5 1.2 28 1480 30 * 6.5 1.2 31 1960 6 - 1/1.0 1.0 0.8 14 200 - 1/1.2 1.2 0.8 15 230 - 1/1.6 1.6 0.8 16 300 - 1/2.0 2.0 0.8 17 380 - 1/2.6 2.6 1.0 20.5 480 0.9 7/0.4 1.2 0.8 14.5 170 1.25 7/0.45 1.35 0.8 15.5 240 2.0 7/0.6 1.8 0.8 16.5 310 3.5 7/0.8 2.4 0.8 18.5 420 5.5 7/1.0 3.0 1.0 21.5 600 8 * 3.4 1.0 22 724 14 * 4.4 1.0 26 1190 22 * 5.5 1.2 31 1770 30 * 6.5 1.2 34 2320 * Compacted conductor 600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 7 - 1/1.0 1.0 0.8 14 210 - 1/1.2 1.2 0.8 15 240 - 1/1.6 1.6 0.8 16 320 - 1/2.0 2.0 0.8 17 410 - 1/2.6 2.6 1.0 20.5 570 0.9 7/0.4 1.2 0.8 14.5 190 1.25 7/0.45 1.35 0.8 15.5 250 2.0 7/0.6 1.8 0.8 16.5 320 3.5 7/0.8 2.4 0.8 18.5 450 5.5 7/1.0 3.0 1.0 21.5 640 8 * 3.4 1.0 22 803 14 * 4.4 1.0 26 1330 22 * 5.5 1.2 31 2000 30 * 6.5 1.2 34 2640EPRN
600V~15kV EPR (Ethylene Propylene Rubber) Insulated Neoprene Sheathed Power Cables (EPRN). It is used at wiring for power and equipment. It shall comply with the standards of ICEA. Features Construction:(1) Conductor: tinned or untinned soft annealed stranded copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: EPR (4) Insulation screen (voltage > 2001V) (5) Tinned copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Sheath: Neoprene Introduction: The EPRN power Cable is used for power distribution system. The EPR insulated Neoprene (Polyvinyl Chloride) sheathed power cable has excellent insulation resistance. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties. ICEA: The Insulated Cable Engineers Association. Specifications 600V EPRN Single Core Power Cable Refer To ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area AWGorMCM Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/0.615 1.85 1.14 6.5 48 300 13 7/0.691 2.08 1.14 6.5 57 300 12 7/0.779 2.34 1.14 7.0 65 300 11 7/0.871 2.62 1.14 7.5 80 300 10 7/0.978 2.95 1.14 7.5 87 300 9 7/1.1 3.30 1.14 8.0 102 300 8 7/1.23 3.70 1.52 9.0 137 300 7 7/1.39 4.16 1.52 10.0 173 300 6 7/1.56 4.67 1.52 10.5 203 300 5 7/1.75 5.24 1.52 11 240 300 4 7/1.95 5.88 1.52 12 286 300 3 7/2.2 6.61 1.52 13.5 343 300 2 7/2.47 7.42 1.52 14.0 414 300 1 19/1.69 8.43 2.03 15.5 550 300 1/0 19/1.89 9.46 2.03 16.5 664 300 2/0 19/2.13 10.6 2.03 18 805 300 3/0 19/2.39 11.9 2.03 20 983 300 4/0 19/2.68 13.4 2.03 21 1203 300 250 37/2.09 14.6 2.41 25.5 1503 300 300 37/2.29 16.1 2.41 26.5 1760 300 350 37/2.47 17.3 2.41 29 2010 300 400 37/2.64 18.5 2.41 30 2260 300 450 37/2.8 19.6 2.41 31 2509 300 500 37/2.95 20.7 2.41 32 2758 200 550 61/2.41 21.7 2.79 34 3060 200 600 61/2.52 22.7 2.79 35 3308 200 650 61/2.6 23.6 2.79 36 3555 200 700 61/2.72 24.5 2.79 37 3802 200 750 61/2.82 25.3 2.79 39 4047 200 800 61/2.91 26.2 2.79 40 4293 200 600V EPRN Two Core Power Cable Refer To ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area AWGorMCM Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/0.615 1.85 1.14 14 150 300 13 7/0.691 2.08 1.14 14.5 170 300 12 7/0.779 2.34 1.14 15.5 206 300 11 7/0.871 2.62 1.14 16.5 239 300 10 7/0.978 2.95 1.14 17.0 258 300 9 7/1.1 3.30 1.14 17.5 293 300 8 7/1.23 3.70 1.52 22 420 300 7 7/1.39 4.16 1.52 24 513 300 6 7/1.56 4.67 1.52 25.5 583 300 5 7/1.75 5.24 1.52 26 667 300 4 7/1.95 5.88 1.52 29 772 300 3 7/2.2 6.61 1.52 30 900 300 2 7/2.47 7.42 1.52 32 1057 300 1 19/1.69 8.43 2.03 34 1304 300 1/0 19/1.89 9.46 2.03 36 1548 300 2/0 19/2.13 10.6 2.03 39 1848 200 3/0 19/2.39 11.9 2.03 42 2234 200 4/0 19/2.68 13.4 2.03 45 2689 200 250 37/2.09 14.6 2.41 53 3363 200 300 37/2.29 16.1 2.41 56 3902 200 350 37/2.47 17.3 2.41 58 4423 200 400 37/2.64 18.5 2.41 61 4946 200 450 37/2.8 19.6 2.41 63 5463 200 500 37/2.95 20.7 2.41 66 5955 200 550 61/2.41 21.7 2.79 70 6616 200 600 61/2.52 22.7 2.79 72 7130 200 650 61/2.6 23.6 2.79 74 7640 200 700 61/2.72 24.5 2.79 78 8350 200 750 61/2.82 25.3 2.79 79 8859 200 800 61/2.91 26.2 2.79 81 9417 200 600V EPRN Three Core Power Cable Refer To ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area AWGorMCM Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/0.615 1.85 1.14 15.5 253 300 13 7/0.691 2.08 1.14 16 288 300 12 7/0.779 2.34 1.14 16.5 320 300 11 7/0.871 2.62 1.14 17 373 300 10 7/0.978 2.95 1.14 17.5 406 300 9 7/1.1 3.30 1.14 19 464 300 8 7/1.23 3.70 1.52 23 729 300 7 7/1.39 4.16 1.52 24 826 300 6 7/1.56 4.67 1.52 26 943 300 5 7/1.75 5.24 1.52 28 1083 300 4 7/1.95 5.88 1.52 29 1258 300 3 7/2.2 6.61 1.52 31 1472 300 2 7/2.47 7.42 1.52 32 1734 300 1 19/1.69 8.43 2.03 35 2141 300 1/0 19/1.89 9.46 2.03 37 2548 300 2/0 19/2.13 10.6 2.03 40 3049 200 3/0 19/2.39 11.9 2.03 43 3674 200 4/0 19/2.68 13.4 2.03 50 4575 200 250 37/2.09 14.6 2.41 56 5590 200 300 37/2.29 16.1 2.41 61 6498 200 350 37/2.47 17.3 2.41 63 7367 200 400 37/2.64 18.5 2.41 66 8241 200 450 37/2.8 19.6 2.41 68 9105 200 500 37/2.95 20.7 2.41 70 9973 200 550 61/2.41 21.7 2.79 74 11084 200 600 61/2.52 22.7 2.79 79 12155 200 650 61/2.6 23.6 2.79 81 13013 200 700 61/2.72 24.5 2.79 83 13874 200 750 61/2.82 25.3 2.79 86 14719 200 800 61/2.91 26.2 2.79 87 15585 200 5KV EPRN Single Core Power Cable Refer to ICEA Conductor Thickness ofinsulation Approx. Overall Diameter Standard Length Normative Cross Area Number/ Diameter of Wires OuterDiameterApprox. AWGorMCM No./mm mm mm mm M 008 07/1.23 03.70 2.29 13.0 300 007 07/1.39 04.16 2.29 14.0 300 006 07/1.56 04.67 2.29 14.5 300 005 07/1.75 05.24 2.29 15.0 300 004 07/1.95 05.88 2.29 15.5 300 003 07/2.20 06.61 2.29 17.5 300 002 07/2.47 07.42 2.29 19.0 300 001 19/1.69 08.43 2.29 20.0 300 1/0 19/1.89 09.46 2.29 21.0 300 2/0 19/2.13 10.60 2.29 22.0 300 3/0 19/2.39 11.90 2.29 23.0 300 4/0 19/2.68 13.40 2.29 25.0 300 250 37/2.09 14.60 2.29 28.0 300 300 37/2.29 16.10 2.29 29.0 300 350 37/2.47 17.30 2.29 31.0 300 400 37/2.64 18.50 2.29 32.0 300 450 37/2.80 19.60 2.29 33.0 300 500 37/2.95 20.70 2.29 34.0 200 550 61/2.41 21.70 2.29 35.0 200 600 61/2.52 22.70 2.29 36.0 200 650 61/2.62 23.60 2.29 37.0 200 700 61/2.72 24.50 2.29 38.0 200 750 61/2.82 25.30 2.29 39.0 200 800 61/2.91 26.20 2.29 41.0 200 5KV EPRN Two Cores Power Cable Refer to ICEA Conductor Thickness ofinsulation Approx. Overall Diameter Standard Length Normative Cross Area Number/ Diameter of Wires OuterDiameterApprox. AWGorMCM No./mm mm mm mm M 008 07/1.23 03.70 2.29 26.0 300 007 07/1.39 04.16 2.29 27.5 300 006 07/1.56 04.67 2.29 28.0 300 005 07/1.75 05.24 2.29 30.0 300 004 07/1.95 05.88 2.29 31.0 300 003 07/2.20 06.61 2.29 33.0 200 002 07/2.47 07.42 2.29 34.0 200 01 19/1.69 08.43 2.29 36.0 200 1/0 19/1.89 09.46 2.29 39.0 200 2/0 19/2.13 10.60 2.29 42.0 200 5KV EPRN Three Cores Power Cable Refer to ICEA Conductor Thickness ofinsulation Approx. Overall Diameter Standard Length Normative Cross Area Number/ Diameter of Wires OuterDiameterApprox. AWGorMCM No./mm mm mm mm M 008 07/1.23 03.70 2.29 27 300 007 07/1.39 04.16 2.29 28 300 006 07/1.56 04.67 2.29 31 300 005 07/1.75 05.24 2.29 32 300 004 07/1.95 05.88 2.29 33 300 003 07/2.20 06.61 2.29 35 200 002 07/2.47 07.42 2.29 36 200 001 19/1.69 08.43 2.29 39 200 1/0 19/1.89 09.46 2.29 42 200 2/0 19/2.13 10.60 2.29 44 200 3/0 19/2.39 11.90 2.29 47 200 4/0 19/2.68 13.40 2.29 53 200 250 37/2.09 14.60 2.29 55 200 300 37/2.29 16.10 2.29 59 200 350 37/2.47 17.30 2.29 62 200 400 37/2.64 18.50 2.29 64 200 450 37/2.80 19.60 2.29 67 200 500 37/2.95 20.70 2.29 70 200 550 61/2.41 21.70 2.29 71 200 600 61/2.52 22.70 2.29 72 200 650 61/2.62 23.60 2.29 74 200 700 61/2.72 24.50 2.29 76 200 750 61/2.82 25.30 2.29 80 200 15KV EPRN Single Core Power Cable Refer to ICEA Conductor Thickness ofinsulation Approx. Overall Diameter Standard Length Normative Cross Area Number/ Diameter of Wires OuterDiameterApprox. AWGorMCM No./mm mm mm mm M 002 07/2.47 07.42 4.45 24 300 001 19/1.69 08.43 4.45 25 300 1/0 19/1.89 09.46 4.45 26 300 2/0 19/2.13 10.60 4.45 28 300 3/0 19/2.39 11.90 4.45 30 300 4/0 19/2.68 13.40 4.45 31 300 250 37/2.09 14.60 4.45 32 300 300 37/2.29 16.10 4.45 34 200 350 37/2.47 17.30 4.45 35 200 400 37/2.64 18.50 4.45 36 200 450 37/2.80 19.60 4.45 37 200 500 37/2.95 20.70 4.45 38 200 550 61/2.41 21.70 4.45 40 200 600 61/2.52 22.70 4.45 40 200 650 61/2.62 23.60 4.45 42 200 700 61/2.72 24.50 4.45 43 200 750 61/2.82 25.30 4.45 44 200 800 61/2.91 26.20 4.45 45 200 15KV EPRN Three Cores Power Cable Refer to ICEA Conductor Thickness ofinsulation Approx. Overall Diameter Standard Length Normative Cross Area Number/ Diameter of Wires OuterDiameterApprox. AWGorMCM No./mm mm mm mm M 002 07/2.47 07.42 4.45 44 200 001 19/1.69 08.43 4.45 46 200 1/0 19/1.89 09.46 4.45 49 200 2/0 19/2.13 10.60 4.45 51 200 3/0 19/2.39 11.90 4.45 54 200 4/0 19/2.68 13.40 4.45 57 200 250 37/2.09 14.60 4.45 60 200 300 37/2.29 16.10 4.45 63 200 350 37/2.47 17.30 4.45 66 200 400 37/2.64 18.50 4.45 68 200 450 37/2.80 19.60 4.45 72 200 500 37/2.95 20.70 4.45 74 200 550 61/2.41 21.70 4.45 77 200 600 61/2.52 22.70 4.45 79 200 650 61/2.62 23.60 4.45 81 200 700 61/2.72 24.50 4.45 83 200 750 61/2.82 25.30 4.45 84 200 800 61/2.91 26.20 4.45 86 200 5KV EPRN Single Core Power Cable Refer to ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 7/1.2 3.6 2.29 13.5 300 14 7/1.6 4.8 2.29 14 300 22 7/2.0 6.0 2.29 16.5 300 30 7/2.3 6.9 2.29 17.5 300 38 72.6 7.8 2.29 19 300 50 19/1.8 9.0 2.29 20 300 60 19/2.0 10.0 2.29 21 300 80 19/2.3 11.5 2.29 23 300 100 19/2.6 13.0 2.29 24 300 125 19/2.9 14.5 2.29 28 300 150 37/2.3 16.1 2.29 29 300 200 37/2.6 18.2 2.29 31 300 250 61/2.3 20.7 2.29 34 200 325 61/2.6 23.4 2.29 37 200 400 61/2.9 26.1 2.29 40 200 5KV EPRN Two Core Power Cable Refer to ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 7/1.2 3.6 2.29 26 300 14 7/1.6 4.8 2.29 29 300 22 7/2.0 6.0 2.29 32 300 30 7/2.3 6.9 2.29 33 200 38 72.6 7.8 2.29 35 200 50 19/1.8 9.0 2.29 39 200 60 19/2.0 10.0 2.29 41 200 5KV EPRN Three Core Power Cable Refer to ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 7/1.2 3.6 2.29 27 300 14 7/1.6 4.8 2.29 31 300 22 7/2.0 6.0 2.29 33 300 30 7/2.3 6.9 2.29 35 200 38 72.6 7.8 2.29 37 200 50 19/1.8 9.0 2.29 41 200 60 19/2.0 10.0 2.29 43 200 80 19/2.3 11.5 2.29 48 200 100 19/2.6 13.0 2.29 52 200 125 19/2.9 14.5 2.29 55 200 150 37/2.3 16.1 2.29 59 200 200 37/2.6 18.2 2.29 64 200 250 61/2.3 20.7 2.29 70 200 325 61/2.6 23.4 2.29 78 200 15KV EPRN Single Core Power Cable Refer to ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 72.6 7.8 4.45 24 300 50 19/1.8 9.0 4.45 26 300 60 19/2.0 10.0 4.45 28 300 80 19/2.3 11.5 4.45 29 300 100 19/2.6 13.0 4.45 31 300 125 19/2.9 14.5 4.45 32 300 150 37/2.3 16.1 4.45 34 200 200 37/2.6 18.2 4.45 36 200 250 61/2.3 20.7 4.45 39 200 325 61/2.6 23.4 4.45 42 200 400 61/2.9 26.1 4.45 45 200 15KV EPRN Three Core Power Cable Refer to ICEA Conductor Thickness of insulation mm Approx. Overall Diameter mm Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 72.6 7.8 4.45 49 200 50 19/1.8 9.0 4.45 53 200 60 19/2.0 10.0 4.45 55 200 80 19/2.3 11.5 4.45 58 200 100 19/2.6 13.0 4.45 61 200 125 19/2.9 14.5 4.45 66 200 150 37/2.3 16.1 4.45 69 200 200 37/2.6 18.2 4.45 74 200 250 61/2.3 20.7 4.45 81 200 325 61/2.6 23.4 4.45 88 200 400 61/2.9 26.1 4.45 94 200CVV-S
600V Grade Polyvinyl Chloride Insulated and Sheathed Control Cables with shields (Code designation: CVV-S). It is used at wiring for control circuit. The cables shall comply with the standard of CNS 12726. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Copper tape screen (5) Sheath: PVC Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC control cable wrap with copper tape shield. Specifications 600V PVC Insulated and PVC Sheathed copper tape screen Control Cable (CVV-S) Number Of cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 2 1.25 7/0.45 1.35 0.8 10.5 130 300 2.0 7/0.6 1.8 0.8 11.0 160 300 3.5 7/0.8 2.4 0.8 12.5 210 300 5.5 7/1.0 3.0 1.0 14.5 290 300 8 7/1.2 3.6 1.2 16.5 385 300 8 * 3.4 1.2 16.0 370 300 14 7/1.6 4.8 1.4 19.5 575 300 14 * 4.4 1.4 19.0 550 300 22 7/2.0 6.0 1.6 23. 825 300 22 * 5.5 1.6 22 780 300 3 1.25 7/0.45 1.35 0.8 11.0 150 300 2.0 7/0.6 1.8 0.8 11.5 190 300 3.5 7/0.8 2.4 0.8 13.0 255 300 5.5 7/1.0 3.0 1.0 15.0 360 300 8 7/1.2 3.6 1.2 17.5 485 300 8 * 3.4 1.2 17.0 465 300 14 7/1.6 4.8 1.4 21 750 300 14 * 4.4 1.4 20 715 300 22 7/2.0 6.0 1.6 25 1090 300 22 * 5.6 1.6 24 1040 300 4 1.25 7/0.45 1.35 0.8 11.5 175 300 2.0 7/0.6 1.8 0.8 12.5 230 300 3.5 7/0.8 2.4 0.8 14.0 315 300 5.5 7/1.0 3.0 1.0 16.5 450 300 5 1.25 7/0.45 1.35 0.8 12.5 170 300 2.0 7/0.6 1.8 0.8 13.5 230 300 3.5 7/0.8 2.4 0.8 15.0 330 300 5.5 7/1.0 3.0 1.0 17.5 480 300 * Compacted stranded conductor 600V PVC Insulated and PVC Sheathed copper tape screen Control Cable (CVV-S) NumberOfcores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 6 1.25 7/0.45 1.35 0.8 13.5 235 300 2.0 7/0.6 1.8 0.8 14.5 310 300 3.5 7/0.8 2.4 0.8 16.5 435 300 5.5 7/1.0 3.0 1.0 19.5 630 300 7 1.25 7/0.45 1.35 0.8 13.5 250 300 2.0 7/0.6 1.8 0.8 14.5 335 300 3.5 7/0.8 2.4 0.8 16.5 475 300 5.5 7/1.0 3.0 1.0 19.5 690 300 8 1.25 7/0.45 1.35 0.8 14.0 280 300 2.0 7/0.6 1.8 0.8 15.5 375 300 3.5 7/0.8 2.4 0.8 17.5 535 300 5.5 7/1.0 3.0 1.0 21 730 300 10 1.25 7/0.45 1.35 0.8 16.0 350 300 2.0 7/0.6 1.8 0.8 18.0 475 300 3.5 7/0.8 2.4 0.8 21 680 300 5.5 7/1.0 3.0 1.0 25 1020 300 12 1.25 7/0.45 1.35 0.8 16.5 390 300 2.0 7/0.6 1.8 0.8 18.5 530 300 3.5 7/0.8 2.4 0.8 21 765 300 5.5 7/1.0 3.0 1.0 26 1160 300 15 1.25 7/0.45 1.35 0.8 17.5 455 300 2.0 7/0.6 1.8 0.8 19.5 630 300 3.5 7/0.8 2.4 0.8 23 930 300 5.5 7/1.0 3.0 1.0 27 1400 300 20 1.25 7/0.45 1.35 0.8 19.5 570 300 2.0 7/0.6 1.8 0.8 22 790 300 3.5 7/0.8 2.4 0.8 25 1190 300 5.5 7/1.0 3.0 1.0 31 1800 300 30 1.25 7/0.45 1.35 0.8 24 800 300 2.0 7/0.6 1.8 0.8 27 1140 300 3.5 7/0.8 2.4 0.8 31 1730 300