600V Grade Polyvinyl Chloride Insulated and Sheathed Control Cables with shields (Code designation: CVV-S). It is used at wiring for control circuit. The cables shall comply with the standard of CNS 12726.
Features
Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Copper tape screen (5) Sheath: PVC Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC control cable wrap with copper tape shield.
Specifications
600V PVC Insulated and PVC Sheathed copper tape screen Control Cable (CVV-S)
* Compacted stranded conductor 600V PVC Insulated and PVC Sheathed copper tape screen Control Cable (CVV-S)
|
更多商品
CVV
600V Grade Polyvinyl Chloride Insulated and Sheathed Control Cables (Code designation: CVV). It is used at wiring for control circuit. The cables shall comply with the standard of CNS 4898. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction:Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC control cable has labeled our National Quality Standard. Specifications 600V PVC Insulated and PVC Sheathed Control Cable (CVV) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 2 1.25 7/0.45 1.35 0.8 9.4 100 300 2.0 7/0.6 1.8 0.8 10.5 130 300 3.5 7/0.8 2.4 0.8 11.5 180 300 5.5 7/1.0 3.0 1.0 13.5 250 300 8 7/1.2 3.6 1.2 15.5 340 300 8 * 3.4 1.2 15.0 330 300 14 7/1.6 4.8 1.4 19.0 530 300 14 * 4.4 1.4 18.0 505 300 22 7/2.0 6.0 1.6 23. 770 300 22 * 5.5 1.6 21 730 300 3 1.25 7/0.45 1.35 0.8 9.9 120 300 2.0 7/0.6 1.8 0.8 11.0 160 300 3.5 7/0.8 2.4 0.8 12.5 225 300 5.5 7/1.0 3.0 1.0 14.5 320 300 8 7/1.2 3.6 1.2 16.5 440 300 8 * 3.4 1.2 16.0 430 300 14 7/1.6 4.8 1.4 20 690 300 14 * 4.4 1.4 19 660 300 22 7/2.0 6.0 1.6 24 1040 300 22 * 5.5 1.6 23 980 300 4 1.25 7/0.45 1.35 0.8 11.0 150 300 2.0 7/0.6 1.8 0.8 12.0 200 300 3.5 7/0.8 2.4 0.8 13.5 280 300 5.5 7/1.0 3.0 1.0 16.0 405 300 8 7/1.2 3.6 1.2 18.0 560 300 8 * 3.4 1.2 17.5 540 300 14 7/1.6 4.8 1.4 23 900 300 14 * 4.4 1.4 21 845 300 22 7/2.0 6.0 1.6 27 1340 300 22 * 5.5 1.6 25 1270 300 * Compacted stranded conductor 600V PVC Insulated and PVC Sheathed Control Cable (CVV) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 5 1.25 7/0.45 1.35 0.8 11.5 175 300 2.0 7/0.6 1.8 0.8 13.0 240 300 3.5 7/0.8 2.4 0.8 14.5 340 300 5.5 7/1.0 3.0 1.0 17.0 490 300 8 7/1.2 3.6 1.2 20 685 300 8 * 3.4 1.2 18.5 660 300 14 7/1.6 4.8 1.4 25 1110 300 14 * 4.4 1.4 24 1050 300 6 1.25 7/0.45 1.35 0.8 12.5 200 300 2.0 7/0.6 1.8 0.8 14.3 280 300 3.5 7/0.8 2.4 0.8 15.5 400 300 5.5 7/1.0 3.0 1.0 18.5 580 300 8 7/1.2 3.6 1.2 22 810 300 8 * 3.4 1.2 21 780 300 14 7/1.6 4.8 1.4 27 1330 300 14 * 4.4 1.4 26 1250 300 7 1.25 7/0.45 1.35 0.8 12.5 220 300 2.0 7/0.6 1.8 0.8 14.0 300 300 3.5 7/0.8 2.4 0.8 15.5 430 300 5.5 7/1.0 3.0 1.0 18.5 640 300 8 7/1.2 3.6 1.2 22 900 300 8 * 3.4 1.2 21 865 300 8 1.25 7/0.45 1.35 0.8 13.5 250 300 2.0 7/0.6 1.8 0.8 15.0 340 300 3.5 7/0.8 2.4 0.8 17.0 500 300 5.5 7/1.0 3.0 1.0 21 730 300 8 7/1.2 3.6 1.2 24 1040 300 8 * 3.4 1.2 23 975 300 * Compacted stranded conductor 600V PVC Insulated and PVC Sheathed Control Cable (CVV) Number Of cores Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 10 1.25 7/0.45 1.35 0.8 15.5 310 300 2.0 7/0.6 1.8 0.8 17.5 430 300 3.5 7/0.8 2.4 0.8 19.5 630 300 5.5 7/1.0 3.0 1.0 24 940 300 8 7/1.2 3.6 1.2 29 1360 300 8 * 3.4 1.2 28 1290 300 12 1.25 7/0.45 1.35 0.8 16.0 350 300 2.0 7/0.6 1.8 0.8 18.0 490 300 3.5 7/0.8 2.4 0.8 21 720 300 5.5 7/1.0 3.0 1.0 25 1100 300 8 7/1.2 3.6 1.2 30 1560 300 8 * 3.4 1.2 29 1500 300 15 1.25 7/0.45 1.35 0.8 17.0 405 300 2.0 7/0.6 1.8 0.8 19.0 575 300 3.5 7/0.8 2.4 0.8 22 855 300 5.5 7/1.0 3.0 1.0 27 1310 300 20 1.25 7/0.45 1.35 0.8 19.0 515 300 2.0 7/0.6 1.8 0.8 22 735 300 3.5 7/0.8 2.4 0.8 25 1130 300 5.5 7/1.0 3.0 1.0 31 1730 300 30 1.25 7/0.45 1.35 0.8 23 735 300 2.0 7/0.6 1.8 0.8 26 1100 300 3.5 7/0.8 2.4 0.8 30 1670 300 * Compacted stranded conductorCV
600V~25KV Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Sheathed Cables. It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 2655. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: XLPE. (4) Insulation screen (voltage > 2001V) (5) Copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Sheath: PVC Introduction: Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce XLPE cable in 1967. Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce 33KV XLPE cable in 1977. In 1977, we invested heavily in strippable insulation screen with three tandem extrusions. In 1985, we developed dry curing method for insulated process. 600V~25KV XLPE power cable has labeled our National Quality Standard. Specifications XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 600V One Core Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.6 1.6 0.76 4.2 49 300 - 1/2.0 2.0 0.76 4.6 63 300 - 1/2.6 2.6 0.76 4.9 87 300 - 1/3.2 3.2 1.14 6.7 128 300 2.0 7/0.6 1.8 0.76 4.4 51 300 3.5 7/0.8 2.4 0.76 5.0 71 300 5.5 7/1.0 3.0 0.76 5.6 94 300 8 7/1.2 3.6 1.14 6.6 134 300 14 7/1.6 4.8 1.14 8.6 203 300 22 7/2.0 6.0 1.14 9.8 288 300 38 7/2.6 7.8 1.40 12.1 450 300 60 19/2.0 10.0 1.40 15.6 679 300 100 19/2.6 13.0 1.40 18.5 1083 300 150 37/2.3 16.1 1.65 23.4 1676 300 200 37/2.6 18.2 1.65 25.5 2091 200 250 61/2.3 20.7 1.65 28.0 2665 200 325 61/2.6 23.4 2.03 31.4 3380 200 400 61/2.9 26.1 2.03 34.1 4147 200 500 61/3.2 28.8 2.03 36.8 4990 150 600 91/2.9 31.9 2.41 38.5 6105 150 800 127/2.8 36.4 2.41 46.9 7883 150 1000 127/3.2 41.6 2.41 52.1 10160 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 600V Two Cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.6 1.6 0.76 9.4 110 300 - 1/2.0 2.0 0.76 10.2 140 300 - 1/2.6 2.6 0.76 11.4 195 300 - 1/3.2 3.2 1.14 14.4 322 300 2.0 7/0.6 1.8 0.76 9.8 116 300 3.5 7/0.8 2.4 0.76 11.0 160 300 5.5 7/1.0 3.0 0.76 12.2 213 300 8 7/1.2 3.6 1.14 16.0 341 300 14 7/1.6 4.8 1.14 18.4 502 300 22 7/2.0 6.0 1.14 20.8 699 300 38 7/2.6 7.8 1.40 26.6 927 300 60 19/2.0 10.0 1.40 31.0 1683 300 100 19/2.6 13.0 1.40 36.8 2615 300 150 37/2.3 16.1 1.65 46.3 4053 300 200 37/2.6 18.2 1.65 50.3 5003 300 250 61/2.3 20.7 1.65 55.3 6313 200 325 61/2.6 23.4 2.03 62.1 7985 200 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 600V Three Cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.6 1.6 0.76 9.9 135 300 - 1/2.0 2.0 0.76 10.8 177 300 - 1/2.6 2.6 0.76 12.1 253 300 - 1/3.2 3.2 1.14 16.1 414 300 2.0 7/0.6 1.8 0.76 10.4 142 300 3.5 7/0.8 2.4 0.76 11.6 200 300 5.5 7/1.0 3.0 0.76 12.9 272 300 8 7/1.2 3.6 1.14 17.0 431 300 14 7/1.6 4.8 1.14 19.5 649 300 22 7/2.0 6.0 1.14 25.1 971 300 38 7/2.6 7.8 1.40 28.3 1533 300 60 19/2.0 10.0 1.40 33.0 2271 300 100 19/2.6 13.0 1.40 39.3 3604 300 150 37/2.3 16.1 1.65 49.4 5560 300 200 37/2.6 18.2 1.65 53.7 6907 200 250 61/2.3 20.7 1.65 59.1 8769 200 325 61/2.6 23.4 2.03 66.5 11120 200 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 600V Four Cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.6 1.6 0.76 10.7 166 300 - 1/2.0 2.0 0.76 11.7 219 300 - 1/2.6 2.6 0.76 13.1 317 300 - 1/3.2 3.2 1.14 16.8 488 300 2.0 7/0.6 1.8 0.76 11.2 174 300 3.5 7/0.8 2.4 0.76 12.7 252 300 5.5 7/1.0 3.0 0.76 14.9 373 300 8 7/1.2 3.6 1.14 18.5 545 300 14 7/1.6 4.8 1.14 22.4 885 300 22 7/2.0 6.0 1.14 25.3 1251 300 38 7/2.6 7.8 1.40 31.1 1960 300 60 19/2.0 10.0 1.40 36.4 2943 300 100 19/2.6 13.0 1.40 45.1 4845 300 150 37/2.3 16.1 1.65 54.5 7191 200 200 37/2.6 18.2 1.65 59.4 8961 200 250 61/2.3 20.7 1.65 65.4 11400 200 325 61/2.6 23.4 2.03 75.2 14760 200 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 601~2000V One Core Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 2.0 7/0.6 1.8 1.14 7.3 56 300 3.5 7/0.8 2.4 1.14 7.9 74 300 5.5 7/1.0 3.0 1.14 8.4 98 300 8 7/1.2 3.6 1.40 9.6 133 300 14 7/1.6 4.8 1.40 11.6 200 300 22 7/2.0 6.0 1.40 12.8 284 300 38 7/2.6 7.8 1.65 15.6 451 300 60 19/2.0 10.0 1.65 18.6 690 300 100 19/2.6 13.0 1.65 21.6 1098 300 150 37/2.3 16.1 1.90 26.3 1692 300 200 37/2.6 18.2 1.90 28.4 2111 300 250 61/2.3 20.7 1.90 30.9 2669 200 325 61/2.6 23.4 2.29 34.4 3391 200 400 61/2.9 26.1 2.29 37.1 4154 200 500 61/3.2 28.8 2.29 39.7 4996 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 601~2000V Three Cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 2.0 7/0.6 1.8 1.14 13.8 179 300 3.5 7/0.8 2.4 1.14 15.0 241 300 5.5 7/1.0 3.0 1.14 18.0 348 300 8 7/1.2 3.6 1.40 20.5 473 300 14 7/1.6 4.8 1.40 23.0 698 300 22 7/2.0 6.0 1.40 28.0 1040 300 38 7/2.6 7.8 1.65 32.8 1615 300 60 19/2.0 10.0 1.65 37.5 2363 300 100 19/2.6 13.0 1.65 44.0 3703 300 125 19/2.9 14.5 1.90 51.8 4751 200 150 37/2.3 16.1 1.90 55.3 5671 200 200 37/2.6 18.2 1.90 60.0 7039 150 250 61/2.3 20.7 1.90 65.0 8853 150 325 61/2.6 23.4 2.29 73.0 11240 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 2001~5000V One Core Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 7/1.2 3.6 2.29 14 244 300 14 7/1.6 4.8 2.29 16 330 300 22 7/2.0 6.0 2.29 17.5 448 300 38 7/2.6 7.8 2.29 19 644 300 60 19/2.0 10.0 2.29 21 897 300 100 19/2.6 13.0 2.29 25 1393 300 150 37/2.3 16.1 2.29 28.5 1950 300 200 37/2.6 18.2 2.29 30.5 2386 300 250 61/2.3 20.7 2.29 33.5 2987 200 325 61/2.6 23.4 2.29 36 3698 200 400 61/2.9 26.1 2.29 39 4510 200 500 61/3.2 28.8 2.29 41.5 5356 150 600 91/2.9 31.9 2.79 50 6678 150 800 127/2.8 36.4 2.79 55 8468 150 1000 127/3.2 41.6 2.79 60 10810 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 2001~5000V Three Cores Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 8 7/1.2 3.6 2.29 29 849 300 14 7/1.6 4.8 2.29 32 1246 300 22 7/2.0 6.0 2.29 34 1431 300 38 7/2.6 7.8 2.29 38 2077 300 60 19/2.0 10.0 2.29 42.5 2899 300 100 19/2.6 13.0 2.29 50.5 4514 300 150 37/2.3 16.1 2.29 57.5 6323 200 200 37/2.6 18.2 2.29 62 7659 150 250 61/2.3 20.7 2.29 68 9668 150 325 61/2.6 23.4 2.29 76 12220 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 5001~8000V One Core; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/1.6 4.8 2.92 17.5 391 300 22 7/2.0 6.0 2.92 19 491 300 38 7/2.6 7.8 2.92 20.5 693 300 60 19/2.0 10.0 2.92 23.5 1003 300 100 19/2.6 13.0 2.92 26.5 1456 300 150 37/2.3 16.1 2.92 30 2018 300 200 37/2.6 18.2 2.92 32 2460 200 250 61/2.3 20.7 2.92 35 3067 200 325 61/2.6 23.4 2.92 37.5 3782 150 400 61/2.9 26.1 2.92 40 4578 150 500 61/3.2 28.8 2.92 43 5452 150 600 91/2.9 31.9 4.45 52 6788 150 800 127/2.8 36.4 4.45 57 8587 150 1000 127/3.2 41.6 4.45 62.5 10940 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 5001~8000V Three Cores; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/1.6 4.8 2.92 34.5 1263 300 22 7/2.0 6.0 2.92 37 1590 300 38 7/2.6 7.8 2.92 41 2256 300 60 19/2.0 10.0 2.92 47 3274 300 100 19/2.6 13.0 2.92 53.5 4750 200 150 37/2.3 16.1 2.92 60.5 6586 150 200 37/2.6 18.2 2.92 65 8011 150 250 61/2.3 20.7 2.92 71 9970 150 325 61/2.6 23.4 2.92 79 12560 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 5001~8000V One Core; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/1.6 4.8 3.56 19 460 300 22 7/2.0 6.0 3.56 20 560 300 38 7/2.6 7.8 3.56 23 790 300 60 19/2.0 10.0 3.56 25 1065 300 100 19/2.6 13.0 3.56 28 1525 300 150 37/2.3 16.1 3.56 31 2095 300 200 37/2.6 18.2 3.56 34 2545 200 250 61/2.3 20.7 3.56 36 3155 200 325 61/2.6 23.4 3.56 39 3880 150 400 61/2.9 26.1 3.56 41.5 4680 150 500 61/3.2 28.8 3.56 46 5735 150 600 91/2.9 31.9 4.45 52 6915 150 800 127/2.8 36.4 4.45 57 8725 150 1000 127/3.2 41.6 4.45 62.5 11090 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 5001~8000V Three Cores; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 14 7/1.6 4.8 3.56 37.5 1500 300 22 7/2.0 6.0 3.56 40 1840 300 38 7/2.6 7.8 3.56 43.5 2450 300 60 19/2.0 10.0 3.56 49 3505 300 100 19/2.6 13.0 3.56 56 4990 200 150 37/2.3 16.1 3.56 63 6865 150 200 37/2.6 18.2 3.56 68.5 8320 150 250 61/2.3 20.7 3.56 74 10570 150 325 61/2.6 23.4 3.56 80 12930 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 8001~15000V One Core ; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 4.45 25 856 300 60 19/2.0 10.0 4.45 27 1130 300 100 19/2.6 13.0 4.45 30 1590 200 150 37/2.3 16.1 4.45 34 2167 200 200 37/2.6 18.2 4.45 36 2628 200 250 61/2.3 20.7 4.45 38 3246 200 325 61/2.6 23.4 4.45 41 3976 200 400 61/2.9 26.1 4.45 43.5 4785 150 500 61/3.2 28.8 4.45 48.5 5850 150 600 91/2.9 31.9 5.59 55 7021 150 800 127/2.8 36.4 5.59 59 8841 150 1000 127/3.2 41.6 5.59 65 11220 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 8001~15000V Three Cores; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 4.45 49.5 2840 200 60 19/2.0 10.0 4.45 54 3744 200 100 19/2.6 13.0 4.45 60.5 5084 150 150 37/2.3 16.1 4.45 68.5 7176 150 200 37/2.6 18.2 4.45 73 8441 150 250 61/2.3 20.7 4.45 80 10920 150 325 61/2.6 23.4 4.45 86 13310 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 8001~15000V One Core; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 5.59 27 964 200 60 19/2.0 10.0 5.59 29.5 1244 200 100 19/2.6 13.0 5.59 33 1721 150 150 37/2.3 16.1 5.59 36 2310 150 200 37/2.6 18.2 5.59 38 2767 150 250 61/2.3 20.7 5.59 40.5 3392 150 325 61/2.6 23.4 5.59 45 4130 150 400 61/2.9 26.1 5.59 47.5 5124 150 500 61/3.2 28.8 5.59 50 6031 150 600 91/2.9 31.9 5.59 55 7266 150 800 127/2.8 36.4 5.59 60 9013 150 1000 127/3.2 41.6 5.59 65 11500 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 8001~15000V Three Cores; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 5.59 54.5 3168 150 60 19/2.0 10.0 5.59 59 4098 150 100 19/2.6 13.0 5.59 66.5 5669 150 150 37/2.3 16.1 5.59 73 7606 150 200 37/2.6 18.2 5.59 80 9369 150 250 61/2.3 20.7 5.59 85 11420 150 325 61/2.6 23.4 5.59 91 13960 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 15001~25000V One Core; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 6.6 29.5 1060 300 60 19/2.0 10.0 6.6 32 1340 300 100 19/2.6 13.0 6.6 35 1850 200 150 37/2.3 16.1 6.6 38 2480 200 200 37/2.6 18.2 6.6 40 2940 200 250 61/2.3 20.7 6.6 42.5 3560 200 325 61/2.6 23.4 6.6 47 4500 200 400 61/2.9 26.1 6.6 50 5390 150 500 61/3.2 28.8 6.6 52 6300 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 15001~25000V Three Cores; Neutral Grounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 6.6 59 3520 200 60 19/2.0 10.0 6.6 64 4440 200 100 19/2.6 13.0 6.6 71 6100 150 150 37/2.3 16.1 6.6 80 8410 150 200 37/2.6 18.2 6.6 84 9930 150 250 61/2.3 20.7 6.6 89 11930 150 325 61/2.6 23.4 6.6 96 14480 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 15001~25000V One Core; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 8.76 34.5 1300 200 60 19/2.0 10.0 8.76 36.5 1590 200 100 19/2.6 13.0 8.76 39.5 2100 150 150 37/2.3 16.1 8.76 43 2740 150 200 37/2.6 18.2 8.76 46.5 3370 150 250 61/2.3 20.7 8.76 49 4060 150 325 61/2.6 23.4 8.76 51.5 4880 150 400 61/2.9 26.1 8.76 54 5740 150 500 61/3.2 28.8 8.76 57 6670 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available. XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV) 15001~25000V Three Cores; Neutral Ungrounded System Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.8 8.76 70 4380 150 60 19/2.0 10.0 8.76 76 5620 150 100 19/2.6 13.0 8.76 83 7280 150 150 37/2.3 16.1 8.76 90 9420 150 200 37/2.6 18.2 8.76 94 10980 150 250 61/2.3 20.7 8.76 99 13230 150 325 61/2.6 23.4 8.76 105 15850 150 For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.CL-SWA
600V~25kV Cross-Linked Polyethylene Insulated, steel wires armor and Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables. It is used at wiring for power distribution system. The power cables shall comply with the standard of IEC 60502. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: XLPE. (4) Insulation screen (voltage > 2001V) (5) Copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Inner Sheath: LSHF (8) Steel wires armor (9) Sheath: LSHF Introduction: 600V~25kV Cross-Linked Polyethylene Insulated, steel wires armor, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables (CL-SWA). It has following characteristics: (1) Low toxicity index; per NES 713; toxicity index <=5 (2) Don’t produce halogen gas; per IEC 60754-1; Amount of HCL gas <=0.5% (3) Low smoke; LSHF compound per ASTM E662 smoke density test; Ds<=250,VOF4<=100 (4) Excellent flame resistance; per ASTM D2863 oxygen index; OI >=30; per IEEE 383 vertical open tray flame test; passed. The Low-Smoke and Halogen-Free (LSHF) wire and cable could minimize the lowest damage in case of fire. Therefore, the public areas, such as subway, tunnel, railway, public building, substreet, ships, power stations, school, hospital, and rapid transit system in more suitable to install the LSHF cable to secure the human lives and properties. Specifications 600V XLPE insulated, steel wire armor, LSHF sheathed cables 1C (CL-SWA) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.0 1.0 0.7 9.9 160 - 1/1.2 1.2 0.7 10.1 170 - 1/1.6 1.6 0.7 10.5 190 - 1/2.0 2.0 0.7 10.9 215 - 1/2.6 2.6 0.7 11.5 250 - 1/3.2 3.2 0.7 12.1 290 2 7/0.6 1.8 0.7 10.7 195 1.25 7/0.45 1.35 0.7 10.4 165 3.5 7/0.8 2.4 0.7 11.3 225 5.5 7/1.0 3.0 0.7 11.9 265 8 7/1.2 3.4 0.7 12.3 300 14 7/1.6 4.4 0.7 13.3 385 22 7/2.0 5.5 0.7 14.4 490 30 7/2.3 6.4 0.9 15.9 605 38 7/2.6 7.3 0.9 16.8 715 50 19/1.8 8.4 1.0 18.2 860 60 19/2.0 9.3 1.0 19.1 995 80 19/2.3 10.7 1.1 22.5 1495 100 19/2.6 12.0 1.1 23.8 1755 125 19/2.9 13.5 1.2 25.5 2075 150 37/2.3 14.7 1.4 27.3 2435 200 37/2.6 17.0 1.6 30.2 2990 250 61/2.3 19.0 1.7 33.6 3870 325 61/2.6 21.7 1.8 36.8 4735 400 61/2.9 24.1 2.0 40.0 5690 500 61/3.2 26.9 2.2 41.1 6740 600V XLPE insulated, steel wire armor, LSHF sheathed cables 2C (CL-SWA) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.0 1.0 0.7 13.0 265 - 1/1.2 1.2 0.7 13.3 281 - 1/1.6 1.6 0.7 14.1 325 - 1/2.0 2.0 0.7 15.0 380 - 1/2.6 2.6 0.7 16.4 470 - 1/3.2 3.2 0.7 17.6 564 2 7/0.6 1.8 0.7 14.7 350 1.25 7/0.45 1.35 0.7 13.9 295 3.5 7/0.8 2.4 0.7 16.0 420 5.5 7/1.0 3.0 0.7 17.1 500 8 7/1.2 3.4 0.7 18.0 575 14 7/1.6 4.4 0.7 20.1 770 22 7/2.0 5.5 0.7 24.0 1295 30 7/2.3 6.4 0.9 26.7 1590 38 7/2.6 7.3 0.9 29.7 1945 50 19/1.8 8.4 1.0 31.6 2255 60 19/2.0 9.3 1.0 34.6 2830 80 19/2.3 10.7 1.1 38.0 3435 100 19/2.6 12.0 1.1 41.1 4070 125 19/2.9 13.5 1.2 46.0 5220 150 37/2.3 14.7 1.4 49.3 6070 200 37/2.6 17.0 1.6 55.6 7455 250 61/2.3 19.0 1.7 60.6 9035 325 61/2.6 21.7 1.8 67.4 10885 400 61/2.9 24.1 2.0 73.6 14060 500 61/3.2 26.9 2.2 81.3 15660 600V XLPE insulated, steel wire armor, LSHF sheathed cables 3C (CL-SWA) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.0 1.0 0.7 13.4 285 - 1/1.2 1.2 0.7 13.8 310 - 1/1.6 1.6 0.7 14.9 370 - 1/2.0 2.0 0.7 15.7 445 - 1/2.6 2.6 0.7 17.0 545 - 1/3.2 3.2 0.7 18.3 665 2 7/0.6 1.8 0.7 15.3 390 1.25 7/0.45 1.35 0.7 14.3 325 3.5 7/0.8 2.4 0.7 16.6 480 5.5 7/1.0 3.0 0.7 17.9 580 8 7/1.2 3.4 0.7 18.7 685 14 7/1.6 4.4 0.7 22.7 1200 22 7/2.0 5.5 0.7 25.1 1555 30 7/2.3 6.4 0.9 28.1 1945 38 7/2.6 7.3 0.9 30.2 2295 50 19/1.8 8.4 1.0 34.5 3040 60 19/2.0 9.3 1.0 36.7 3500 80 19/2.3 10.7 1.1 40.5 4325 100 19/2.6 12.0 1.1 43.6 5190 125 19/2.9 13.5 1.2 48.7 6600 150 37/2.3 14.7 1.4 52.7 7720 200 37/2.6 17.0 1.6 59.4 9610 250 61/2.3 19.0 1.7 64.5 11725 325 61/2.6 21.7 1.8 71.8 14510 400 61/2.9 24.1 2.0 79.9 18420 500 61/3.2 26.9 2.2 87.9 21930 600V XLPE insulated, steel wire armor, LSHF sheathed cables 4C (CL-SWA) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm - 1/1.0 1.0 0.7 14.1 320 - 1/1.2 1.2 0.7 14.7 355 - 1/1.6 1.6 0.7 15.7 425 - 1/2.0 2.0 0.7 16.7 500 - 1/2.6 2.6 0.7 18.1 635 - 1/3.2 3.2 0.7 19.6 785 2 7/0.6 1.8 0.7 16.2 405 1.25 7/0.45 1.35 0.7 15.1 365 3.5 7/0.8 2.4 0.7 17.4 555 5.5 7/1.0 3.0 0.7 19.1 680 8 7/1.2 3.4 0.7 20.3 815 14 7/1.6 4.4 0.7 24.3 1420 22 7/2.0 5.5 0.7 27.1 1890 30 7/2.3 6.4 0.9 30.5 2370 38 7/2.6 7.3 0.9 33.8 3055 50 19/1.8 8.4 1.0 37.3 3705 60 19/2.0 9.3 1.0 39.9 5395 80 19/2.3 10.7 1.1 45.3 5825 100 19/2.6 12.0 1.1 48.8 6895 125 19/2.9 13.5 1.2 53.5 8195 150 37/2.3 14.7 1.4 57.8 9690 200 37/2.6 17.0 1.6 64.9 12015 250 61/2.3 19.0 1.7 70.8 14780 325 61/2.6 21.7 1.8 80.5 19260 400 61/2.9 24.1 2.0 87.9 23195 500 61/3.2 26.9 2.2 96.6 27620CL
600V~25kV Cross-Linked Polyethylene Insulated and Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power and Control Cables. It is used at wiring for power and control circuit of distribution system. The control cables shall comply with the standard of IEC 60502. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: XLPE. (4) Insulation screen (voltage > 2001V) (5) Copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Sheath: LSHF Introduction: 600V~25kV Cross-Linked Polyethylene Insulated and Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power and Control Cables (CL). It has following characteristics: (1) Low toxicity index; per NES 713; toxicity index <=5 (2) Don’t produce halogen gas; per IEC 60754-1; Amount of HCL gas <=0.5% (3) Low smoke; LSHF compound per ASTM E662 smoke density test; Ds<=250,VOF4<=100 (4) Excellent flame resistance; per ASTM D2863 oxygen index; OI >=30; per IEEE 383 vertical open tray flame test; passed. The Low-Smoke and Halogen-Free (LSHF) wire and cable could minimize the lowest damage in case of fire. Therefore, the public areas, such as subway, tunnel, railway, public building, substreet, ships, power stations, school, hospital, and rapid transit system in more suitable to install the LSHF cable to secure the human lives and properties. Specifications 600V XLPE Insulated and LSHF sheathed cables 1C (CL) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 1.25 7/0.45 1.35 0.7 6.2 45 2.0 7/0.6 1.8 0.7 6.6 55 3.5 7/0.8 2.4 0.7 7.2 75 5.5 7/1.0 3.0 0.7 7.8 100 8 7/1.2 3.4 0.7 8.2 125 14 7/1.6 4.4 0.7 9.2 190 22 7/2.0 5.5 0.7 10.3 275 30 7/2.3 6.4 0.9 11.6 355 38 7/2.6 7.3 0.9 12.5 435 50 19/1.8 8.4 1.0 13.9 550 60 19/2.0 9.3 1.0 14.8 665 80 19/2.3 10.7 1.1 16.5 860 100 19/2.6 12.0 1.1 17.9 1080 125 19/2.9 13.5 1.2 19.7 1330 150 37/2.3 14.7 1.4 21.5 1625 200 37/2.6 17.0 1.6 24.3 2060 250 61/2.3 19.0 1.7 26.7 2625 325 61/2.6 21.7 1.8 29.9 3335 400 61/2.9 24.1 2.0 32.9 4130 500 61/3.2 26.9 2.2 36.3 5005 600V XLPE Insulated and LSHF sheathed cables 2C (CL) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 1.25 7/0.45 1.35 0.7 10.4 110 2.0 7/0.6 1.8 0.7 11.3 135 3.5 7/0.8 2.4 0.7 12.5 180 5.5 7/1.0 3.0 0.7 13.7 235 8 7/1.2 3.4 0.7 14.5 295 14 7/1.6 4.4 0.7 16.5 440 22 7/2.0 5.5 0.7 18.7 625 30 7/2.3 6.4 0.9 21.3 810 38 7/2.6 7.3 0.9 24.1 1025 50 19/1.8 8.4 1.0 25.8 1265 60 19/2.0 9.3 1.0 27.7 1520 80 19/2.3 10.7 1.1 31.1 1965 100 19/2.6 12.0 1.1 34.0 2470 125 19/2.9 13.5 1.2 37.6 3040 150 37/2.3 14.7 1.4 41.0 3705 200 37/2.6 17.0 1.6 47.0 4735 250 61/2.3 19.0 1.7 51.7 6010 325 61/2.6 21.7 1.8 58.2 7470 400 61/2.9 24.1 2.0 64.1 9445 500 61/3.2 26.9 2.2 71.0 11485 600V XLPE Insulated and LSHF sheathed cables 3C (CL) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 1.25 7/0.45 1.35 0.7 10.9 110 2.0 7/0.6 1.8 0.7 11.8 135 3.5 7/0.8 2.4 0.7 13.1 180 5.5 7/1.0 3.0 0.7 14.4 235 8 7/1.2 3.4 0.7 15.3 295 14 7/1.6 4.4 0.7 17.4 440 22 7/2.0 5.5 0.7 19.8 625 30 7/2.3 6.4 0.9 22.6 810 38 7/2.6 7.3 24.5 24.5 1025 50 19/1.8 8.4 1.0 27.4 1265 60 19/2.0 9.3 1.0 29.6 1520 80 19/2.3 10.7 1.1 33.2 1965 100 19/2.6 12.0 1.1 36.3 2470 125 19/2.9 13.5 1.2 40.3 3040 150 37/2.3 14.7 1.4 43.9 3705 200 37/2.6 17.0 1.6 50.4 4735 250 61/2.3 19.0 1.7 55.6 6010 325 61/2.6 21.7 1.8 62.4 7470 400 61/2.9 24.1 2.0 68.9 9445 500 61/3.2 26.9 2.2 76.3 11485 600V XLPE Insulated and LSHF sheathed cables 4C (CL) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 1.25 7/0.45 1.35 0.7 11.7 150 2.0 7/0.6 1.8 0.7 12.7 160 3.5 7/0.8 2.4 0.7 14.2 275 5.5 7/1.0 3.0 0.7 15.6 370 8 7/1.2 3.4 0.7 16.5 480 14 7/1.6 4.4 0.7 19.0 750 22 7/2.0 5.5 0.7 21.6 1010 30 7/2.3 6.4 0.9 24.8 1430 38 7/2.6 7.3 24.5 26.6 1780 50 19/1.8 8.4 1.0 30.1 2280 60 19/2.0 9.3 1.0 32.4 2760 80 19/2.3 10.7 1.1 36.6 3600 100 19/2.6 12.0 1.1 40.1 4535 125 19/2.9 13.5 1.2 44.5 5600 150 37/2.3 14.7 1.4 48.5 6850 200 37/2.6 17.0 1.6 55.5 8745 250 61/2.3 19.0 1.7 61.3 11150 325 61/2.6 21.7 1.8 69.0 12400 400 61/2.9 24.1 2.0 76.3 17600 500 61/3.2 26.9 2.2 84.5 21380 22KV XLPE insulated and LSHF sheathed cables 1C (CL) Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 38 7/2.6 7.3 5.5 25.8 882 60 19/2.0 9.3 5.5 28.7 1183 80 19/2.3 10.7 5.5 29.5 1382 100 19/2.6 12.0 5.5 30.9 1635 125 19/2.9 13.5 5.5 33.3 1960 200 37/2.6 17.0 5.5 37.2 2758 250 61/2.3 19.0 5.5 39.2 3347 325 61/2.6 21.7 5.5 42.6 4149 400 61/2.9 24.1 5.5 44.3 4911 22KV XLPE insulated and LSHF sheathed cables 3C (CL) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 38 7/2.6 7.3 5.5 53.9 3254 60 19/2.0 9.3 5.5 60.2 4195 80 19/2.3 10.7 5.5 62.0 4860 100 19/2.6 12.0 5.5 64.7 5659 125 19/2.9 13.5 5.5 70.2 6589 200 37/2.6 17.0 5.5 78.4 9458 250 61/2.3 19.0 5.5 83.1 11459 325 61/2.6 21.7 5.5 90.4 141252PNCT
600V Second Type EPR (Ethylene Propylene Rubber) Insulated Neoprene Sheathed Flexible Cables (2PNCT). It shall comply with the standard of CNS 10741. Features Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: EPR (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: Neoprene Introduction: The 2PNCT portable Cable with flexible conductor is used for Electric Machinery and Apparatus. The EPR insulated Neoprene (Polyvinyl Chloride) sheathed portable cable has excellent flexibility. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties. Specifications 600V 2PNCT SINGLE CORE CABLE Refer to CNS 10741 Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 0.75 30/0.18 1.1 0.8 5.8 48 200 1.25 50/0.18 1.5 0.8 6.2 60 200 2.0 37/0.26 1.8 0.8 6.5 70 200 3.5 45/0.32 2.5 0.8 7.4 95 200 5.5 70/0.32 3.1 1.0 8.4 130 200 8 50/0.45 3.7 1.0 9.2 165 200 14 88/0.45 4.9 1.0 11.0 240 200 22 7/20/0.45 7.0 1.2 13.5 375 200 30 7/27/0.45 8.1 1.2 15.0 470 200 38 7/34/0.45 9.1 1.2 16.0 570 200 50 19/16/0.45 10.4 1.5 18.0 720 200 60 19/20/0.45 11.6 1.5 19.5 870 200 80 19/27/0.45 13.5 2.0 23 1180 200 100 19/34/0.45 15.2 2.0 25 1430 200 600V 2PNCT TWO CORE CABLE Refer to CNS 10741 Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 0.75 30/0.18 1.1 0.8 9.0 115 200 1.25 50/0.18 1.5 0.8 9.8 140 200 2.0 37/0.26 1.8 0.8 11.0 175 200 3.5 45/0.32 2.5 0.8 12.5 245 200 5.5 70/0.32 3.1 1.0 14.5 350 200 8 50/0.45 3.7 1.0 16.0 435 200 14 88/0.45 4.9 1.0 18.5 640 200 22 7/20/0.45 7.0 1.2 25 1070 200 30 7/27/0.45 8.1 1.2 27 1340 200 38 7/34/0.45 9.1 1.2 30 1630 200 50 19/16/0.45 10.4 1.5 34 2100 200 60 19/20/0.45 11.6 1.5 37 2520 200 80 19/27/0.45 13.5 2.0 43 3470 200 100 19/34/0.45 15.2 2.0 47 4200 200 600V 2PNCT THREE CORE CABLE Refer to CNS 10741 Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm 0.75 30/0.18 1.1 0.8 10.5 160 200 1.25 50/0.18 1.5 0.8 11.5 195 200 2.0 37/0.26 1.8 0.8 12.5 245 200 3.5 45/0.32 2.5 0.8 14.5 355 200 5.5 70/0.32 3.1 1.0 17.0 515 200 8 50/0.45 3.7 1.0 18.5 655 200 14 88/0.45 4.9 1.0 22 1000 200 22 7/20/0.45 7.0 1.2 29 1670 200 30 7/27/0.45 8.1 1.2 32 2100 200 38 7/34/0.45 9.1 1.2 35 2550 200 50 19/16/0.45 10.4 1.5 40 3320 200 60 19/20/0.45 11.6 1.5 44 4020 200 80 19/27/0.45 13.5 2.0 51 5500 200 100 19/34/0.45 15.2 2.0 56 6720 200 600V 2PNCT FOUR CORE CABLE Refer to CNS 10741 Conductor Thickness of insulation mm Approx.Overall Diameter mm Approx.Weight Kg/km StandardLength M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer DiameterApprox. mm 0.75 30/0.18 1.1 0.8 9.4 130 200 1.25 50/0.18 1.5 0.8 10.5 175 200 2.0 37/0.26 1.8 0.8 11.5 200 200 3.5 45/0.32 2.5 0.8 13.0 290 200 5.5 70/0.32 3.1 1.0 15.5 415 200 8 50/0.45 3.7 1.0 17.0 525 200 14 88/0.45 4.9 1.0 20 795 200 22 7/20/0.45 7.0 1.2 27 1330 200 30 7/27/0.45 8.1 1.2 29 1670 200 38 7/34/0.45 9.1 1.2 32 2020 200 50 19/16/0.45 10.4 1.5 36 2620 200 60 19/20/0.45 11.6 1.5 39 3150 200 80 19/27/0.45 13.5 2.0 46 4320 200 100 19/34/0.45 15.2 2.0 50 5270 200XLPE69KV
69KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables. It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A007. Features Construction:(1) Conductor: untinned soft annealed stranded copper wires (2) Conductor screen (3) Insulation: XLPE. (4) Insulation screen (5) Copper wires screen (6) Binding tape wraping (7) Sheath: PVC Introduction: The 69KV power cable is apply at high voltage transmission and distribution of electrical energy.The 69KV extra high-voltage XLPE power cable have developed successfully in 1992.The 69KV XLPE power cable has certified by Taiwan Power Company in 1993.The laying off and jointing work of 69KV XLPE power cable has qualified by Taiwan Power Company in 1995. Specifications 69KV XLPE Insulated and PVC Sheathed Power Cable Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Shape Of Conductor Outer Diameter Approx. mm 100 Round Compact 12.0 16.51 63.0 5000 250 150 14.7 16.51 65.5 5700 250 200 17.0 16.51 68.0 6250 250 250 19.0 16.51 70.5 6950 250 325 21.7 16.51 73.5 7800 250 400 24.1 16.51 76.0 8700 250 500 26.9 16.51 79.5 9900 250 600 29.5 16.51 82.5 11150 250 800 4or 5 segmental 34.0 16.51 88.5 13350 250 1000 38.0 16.51 92.0 15350 250 1200 41.7 16.51 96.5 17400 250 1400 45.0 16.51 99.5 19500 250 1600 48.2 16.51 103.0 21460 250XLPE161KV
161KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables. It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A046. Features Construction:(1) Conductor: untinned soft annealed stranded copper wires (2) Conductor screen (3) Insulation: XLPE. (4) Insulation screen (5) Copper wires screen (6) Binding tape and Metal tape wraping (7) Sheath: PVC Introduction: The 161KV power cable is apply at high voltage transmission and distribution of electrical energy.The 161KV extra high-voltage XLPE power cable have developed successfully in 1992. The laying off and jointing work of 161KV XLPE power cable has qualified by Taiwan Power Company in 1997.The 161KV XLPE power cable has certified by Taiwan Power Company in 1999.Pass the 365days long-term cycling test of 161KV extra high-voltage power cable approved by Taiwan Power Company. Specifications 161KV XLPE Insulated and PVC Sheathed Power Cable Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Shape Of Conductor Outer Diamete rApprox. mm 200 Round Compact 17.0 23 84.0 9460 250 250 19.0 23 86.0 10200 250 325 21.7 23 88.7 11100 250 400 24.1 23 91.1 12060 250 500 26.9 23 93.9 13110 250 600 29.5 23 97.5 14650 250 800 4or 5 segmental 34.0 23 104.0 17020 250 1000 38.0 23 109.0 19370 250 1200 41.7 23 111.7 21520 250 1400 45.0 23 116.0 23700 250 1600 48.2 23 119.2 25740 250 1800 51.0 23 123.0 28080 250 2000 53.8 23 125.8 30200 250VV
600V Grade Polyvinyl Chloride Insulated and Sheathed Cables (Code designation: VV). It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 3301. Features Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction: Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC insulated power cable has labeled our National Quality Standard. Specifications 600V Single Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 2.3 5.6 40 300 - 1/1.2 1.2 2.3 5.8 45 300 - 1/1.6 1.6 2.3 6.2 60 300 - 1/2.0 2.0 2.3 6.6 85 300 - 1/2.6 2.6 2.5 7.6 105 300 - 1/3.2 3.2 2.7 8.6 140 300 2.0 7/0.6 1.8 2.3 6.4 65 300 3.5 7/0.8 2.4 2.3 7.0 85 300 5.5 7/1.0 3.0 2.5 8.0 115 300 8 7/1.2 3.6 2.7 9.0 155 300 8 * 3.4 2.7 8.8 150 300 14 7/1.6 4.8 2.9 11.0 235 300 14 * 4.4 2.9 10.5 225 300 22 7/2.0 6.0 3.1 12.5 335 300 22 * 5.5 3.1 12.0 325 300 30 7/2.3 6.9 3.1 13.0 410 300 30 * 6.4 3.1 12.5 400 300 38 7/2.6 7.8 3.3 14.5 515 300 38 * 7.3 3.3 14.0 505 300 50 19/1.8 9.0 3.3 16.0 625 300 50 * 8.4 3.3 15.0 600 300 60 19/2.0 10.0 3.3 17.0 750 300 60 * 9.3 3.3 16.0 725 300 80 19/2.3 11.5 3.5 18.5 960 300 80 * 10.7 3.5 17.5 935 300 100 19/2.6 13.0 3.5 20.0 1270 300 100 * 12.0 3.5 19.0 1150 300 125 19/2.9 14.5 3.8 23.0 1440 300 125 * 13.5 3.7 22.0 1400 300 150 37/2.3 16.1 3.8 24 1760 300 150 * 14.7 3.8 23 1660 300 200 37/2.6 18.2 4.1 27 2220 200 200 * 17.0 4.1 26 2170 200 250 61/2.3 20.7 4.2 30 2810 200 250 * 19.0 4.2 28 2670 200 325 61/2.6 23.4 4.5 33 3550 150 325 * 21.7 4.5 31 3430 150 400 61/2.9 26.1 4.7 36 4360 150 400 * 24.1 4.6 34 4160 150 500 61/3.2 28.8 5.0 39 5290 100 500 * 25.9 4.9 37 5200 100 * Compacted stranded conductor 600V TWO-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 8.7 85 300 - 1/1.2 1.2 0.8 9.1 95 300 - 1/1.6 1.6 0.8 9.9 130 300 - 1/2.0 2.0 0.8 11.0 160 300 - 1/2.6 2.6 1.0 13.0 240 200 - 1/3.2 3.2 1.2 15.0 335 150 2.0 7/0.6 1.8 0.8 10.5 135 300 3.5 7/0.8 2.4 0.8 11.5 180 200 5.5 7/1.0 3.0 1.0 13.5 260 150 8 7/1.2 3.6 1.2 15.5 360 150 8 * 3.4 1.2 15.5 330 300 14 7/1.6 4.8 1.4 19.0 555 300 14 * 4.4 1.4 18.0 505 300 22 7/2.0 6.0 1.6 23 815 300 22 * 5.5 1.6 21 730 300 30 7/2.3 6.9 1.6 24 935 300 30 * 6.4 1.6 23 925 300 38 7/2.6 7.8 1.8 27 1250 300 38 * 7.3 1.8 26 1170 300 50 19/1.8 9.0 1.8 29 1520 300 50 * 8.4 1.8 28 1440 300 60 19/2.0 10.0 1.8 32 1820 300 60 * 9.3 1.8 31 1700 300 80 19/2.3 11.5 2.0 36 2360 300 80 * 10.7 2.0 34 2240 300 100 19/2.6 13.0 2.0 39 2900 300 100 * 12.0 2.0 37 2680 300 125 19/2.9 14.5 2.2 43 3500 300 125 * 13.5 2.2 41 3340 300 150 37/2.3 16.1 2.2 47 4100 300 150 * 14.7 2.2 44 3870 300 200 37/2.6 18.2 2.4 52 5170 200 200 * 17.0 2.4 50 5090 200 250 61/2.3 20.7 2.4 58 6530 200 250 * 19.0 2.4 54 6210 200 325 61/2.6 23.4 2.6 64 8230 150 325 * 21.7 2.6 61 8000 150 *Compacted stranded conductor 600V THREE-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 9.1 100 300 - 1/1.2 1.2 0.8 9.5 120 300 - 1/1.6 1.6 0.8 10.5 155 200 - 1/2.0 2.0 0.8 11.5 200 150 - 1/2.6 2.6 1.0 13.5 305 150 - 1/3.2 3.2 1.2 16.0 435 300 2.0 7/0.6 1.8 0.8 11.0 165 200 3.5 7/0.8 2.4 0.8 12.5 235 200 5.5 7/1.0 3.0 1.0 14.5 335 150 8 7/1.2 3.6 1.2 16.5 465 300 8 * 3.4 1.2 16.0 435 300 14 7/1.6 4.8 1.4 20 740 300 14 * 4.4 1.4 19 670 300 22 7/2.0 6.0 1.6 24 1070 300 22 * 5.5 1.6 23 1000 300 30 7/2.3 6.9 1.6 26 1340 300 30 * 6.4 1.6 24 1290 300 38 7/2.6 7.8 1.8 29 1690 300 38 * 7.3 1.8 28 1630 300 50 19/1.8 9.0 1.8 31 2090 300 50 * 8.4 1.8 30 2010 300 60 19/2.0 10.0 1.8 34 2480 300 60 * 9.3 1.8 33 2370 300 80 19/2.3 11.5 2.0 38 3250 300 80 * 10.7 2.0 36 3120 300 100 19/2.6 13.0 2.0 42 3990 300 100 * 12.0 2.0 40 3780 300 125 19/2.9 14.5 2.2 46 4910 300 125 * 13.5 2.2 44 4720 300 150 37/2.3 16.1 2.2 50 5810 300 150 * 14.7 2.2 47 5520 300 200 37/2.6 18.2 2.4 56 7330 200 200 * 17.0 2.4 53 7260 200 250 61/2.3 20.7 2.4 62 9300 200 250 * 19.0 2.4 58 8980 200 325 61/2.6 23.4 2.6 69 11780 150 325 * 21.7 2.6 65 11530 150 *Compacted stranded conductor 600V FOUR-Core PVC Insulated PVC Sheathed Power Cable (VV) Conductor Thickness of insulation mm Approx. Overall Diameter mm Approx. Weight Kg/km Standard Length M Normative Cross Area mm2 Number/ Diameter of Wires No./mm Outer Diameter Approx. mm - 1/1.0 1.0 0.8 9.8 125 300 - 1/1.2 1.2 0.8 10.5 145 200 - 1/1.6 1.6 0.8 11.5 190 200 - 1/2.0 2.0 0.8 12.5 250 150 - 1/2.6 2.6 1.0 15.0 385 300 - 1/3.2 3.2 1.2 17.0 550 300 2.0 7/0.6 1.8 0.8 12.0 200 200 3.5 7/0.8 2.4 0.8 13.5 290 150 5.5 7/1.0 3.0 1.0 16.0 420 300 8 7/1.2 3.6 1.2 18.0 590 300 8 * 3.4 1.2 17.5 550 300 14 7/1.6 4.8 1.4 22 945 300 14 * 4.4 1.4 21 875 300 22 7/2.0 6.0 1.6 27 1390 300 22 * 5.5 1.6 25 1290 300 30 7/2.3 6.9 1.6 29 1720 300 30 * 6.4 1.6 27 1650 300 38 7/2.6 7.8 1.8 32 2180 300 38 * 7.3 1.8 31 2100 300 50 19/1.8 9.0 1.8 35 2690 300 50 * 8.4 1.8 33 2600 300 60 19/2.0 10.0 1.8 38 3210 300 60 * 9.3 1.8 36 3090 300 80 19/2.3 11.5 2.0 42 4200 300 80 * 10.7 2.0 40 4070 300 100 19/2.6 13.0 2.0 47 5200 300 100 * 12.0 2.0 44 4950 300 125 19/2.9 14.5 2.2 51 6380 300 125 * 13.5 2.2 49 6150 300 150 37/2.3 16.1 2.2 56 7550 300 150 * 14.7 2.2 52 7210 300 200 37/2.6 18.2 2.4 62 9590 200 200 * 17.0 2.4 59 9480 200 250 61/2.3 20.7 2.4 69 12200 200 250 * 19.0 2.4 65 11750 200 325 61/2.6 23.4 2.6 77 15240 150 325 * 21.7 2.6 73 15100 150 *Compacted stranded conductor