商品名稱:

CV

詳細介紹:

600V~25KV Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Sheathed Cables. It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 2655.

Features

Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: XLPE. (4) Insulation screen (voltage > 2001V) (5) Copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Sheath: PVC Introduction: Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce XLPE cable in 1967. Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce 33KV XLPE cable in 1977. In 1977, we invested heavily in strippable insulation screen with three tandem extrusions. In 1985, we developed dry curing method for insulated process. 600V~25KV XLPE power cable has labeled our National Quality Standard.

Specifications

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

600V One Core

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

-

1/1.6

1.6

0.76

4.2

49

300

-

1/2.0

2.0

0.76

4.6

63

300

-

1/2.6

2.6

0.76

4.9

87

300

-

1/3.2

3.2

1.14

6.7

128

300

2.0

7/0.6

1.8

0.76

4.4

51

300

3.5

7/0.8

2.4

0.76

5.0

71

300

5.5

7/1.0

3.0

0.76

5.6

94

300

8

7/1.2

3.6

1.14

6.6

134

300

14

7/1.6

4.8

1.14

8.6

203

300

22

7/2.0

6.0

1.14

9.8

288

300

38

7/2.6

7.8

1.40

12.1

450

300

60

19/2.0

10.0

1.40

15.6

679

300

100

19/2.6

13.0

1.40

18.5

1083

300

150

37/2.3

16.1

1.65

23.4

1676

300

200

37/2.6

18.2

1.65

25.5

2091

200

250

61/2.3

20.7

1.65

28.0

2665

200

325

61/2.6

23.4

2.03

31.4

3380

200

400

61/2.9

26.1

2.03

34.1

4147

200

500

61/3.2

28.8

2.03

36.8

4990

150

600

91/2.9

31.9

2.41

38.5

6105

150

800

127/2.8

36.4

2.41

46.9

7883

150

1000

127/3.2

41.6

2.41

52.1

10160

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

600V Two Cores

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

-

1/1.6

1.6

0.76

9.4

110

300

-

1/2.0

2.0

0.76

10.2

140

300

-

1/2.6

2.6

0.76

11.4

195

300

-

1/3.2

3.2

1.14

14.4

322

300

2.0

7/0.6

1.8

0.76

9.8

116

300

3.5

7/0.8

2.4

0.76

11.0

160

300

5.5

7/1.0

3.0

0.76

12.2

213

300

8

7/1.2

3.6

1.14

16.0

341

300

14

7/1.6

4.8

1.14

18.4

502

300

22

7/2.0

6.0

1.14

20.8

699

300

38

7/2.6

7.8

1.40

26.6

927

300

60

19/2.0

10.0

1.40

31.0

1683

300

100

19/2.6

13.0

1.40

36.8

2615

300

150

37/2.3

16.1

1.65

46.3

4053

300

200

37/2.6

18.2

1.65

50.3

5003

300

250

61/2.3

20.7

1.65

55.3

6313

200

325

61/2.6

23.4

2.03

62.1

7985

200

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

600V Three Cores

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

-

1/1.6

1.6

0.76

9.9

135

300

-

1/2.0

2.0

0.76

10.8

177

300

-

1/2.6

2.6

0.76

12.1

253

300

-

1/3.2

3.2

1.14

16.1

414

300

2.0

7/0.6

1.8

0.76

10.4

142

300

3.5

7/0.8

2.4

0.76

11.6

200

300

5.5

7/1.0

3.0

0.76

12.9

272

300

8

7/1.2

3.6

1.14

17.0

431

300

14

7/1.6

4.8

1.14

19.5

649

300

22

7/2.0

6.0

1.14

25.1

971

300

38

7/2.6

7.8

1.40

28.3

1533

300

60

19/2.0

10.0

1.40

33.0

2271

300

100

19/2.6

13.0

1.40

39.3

3604

300

150

37/2.3

16.1

1.65

49.4

5560

300

200

37/2.6

18.2

1.65

53.7

6907

200

250

61/2.3

20.7

1.65

59.1

8769

200

325

61/2.6

23.4

2.03

66.5

11120

200

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

600V Four Cores

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

-

1/1.6

1.6

0.76

10.7

166

300

-

1/2.0

2.0

0.76

11.7

219

300

-

1/2.6

2.6

0.76

13.1

317

300

-

1/3.2

3.2

1.14

16.8

488

300

2.0

7/0.6

1.8

0.76

11.2

174

300

3.5

7/0.8

2.4

0.76

12.7

252

300

5.5

7/1.0

3.0

0.76

14.9

373

300

8

7/1.2

3.6

1.14

18.5

545

300

14

7/1.6

4.8

1.14

22.4

885

300

22

7/2.0

6.0

1.14

25.3

1251

300

38

7/2.6

7.8

1.40

31.1

1960

300

60

19/2.0

10.0

1.40

36.4

2943

300

100

19/2.6

13.0

1.40

45.1

4845

300

150

37/2.3

16.1

1.65

54.5

7191

200

200

37/2.6

18.2

1.65

59.4

8961

200

250

61/2.3

20.7

1.65

65.4

11400

200

325

61/2.6

23.4

2.03

75.2

14760

200

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

601~2000V One Core

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

2.0

7/0.6

1.8

1.14

7.3

56

300

3.5

7/0.8

2.4

1.14

7.9

74

300

5.5

7/1.0

3.0

1.14

8.4

98

300

8

7/1.2

3.6

1.40

9.6

133

300

14

7/1.6

4.8

1.40

11.6

200

300

22

7/2.0

6.0

1.40

12.8

284

300

38

7/2.6

7.8

1.65

15.6

451

300

60

19/2.0

10.0

1.65

18.6

690

300

100

19/2.6

13.0

1.65

21.6

1098

300

150

37/2.3

16.1

1.90

26.3

1692

300

200

37/2.6

18.2

1.90

28.4

2111

300

250

61/2.3

20.7

1.90

30.9

2669

200

325

61/2.6

23.4

2.29

34.4

3391

200

400

61/2.9

26.1

2.29

37.1

4154

200

500

61/3.2

28.8

2.29

39.7

4996

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

601~2000V Three Cores

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

2.0

7/0.6

1.8

1.14

13.8

179

300

3.5

7/0.8

2.4

1.14

15.0

241

300

5.5

7/1.0

3.0

1.14

18.0

348

300

8

7/1.2

3.6

1.40

20.5

473

300

14

7/1.6

4.8

1.40

23.0

698

300

22

7/2.0

6.0

1.40

28.0

1040

300

38

7/2.6

7.8

1.65

32.8

1615

300

60

19/2.0

10.0

1.65

37.5

2363

300

100

19/2.6

13.0

1.65

44.0

3703

300

125

19/2.9

14.5

1.90

51.8

4751

200

150

37/2.3

16.1

1.90

55.3

5671

200

200

37/2.6

18.2

1.90

60.0

7039

150

250

61/2.3

20.7

1.90

65.0

8853

150

325

61/2.6

23.4

2.29

73.0

11240

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

2001~5000V One Core

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

8

7/1.2

3.6

2.29

14

244

300

14

7/1.6

4.8

2.29

16

330

300

22

7/2.0

6.0

2.29

17.5

448

300

38

7/2.6

7.8

2.29

19

644

300

60

19/2.0

10.0

2.29

21

897

300

100

19/2.6

13.0

2.29

25

1393

300

150

37/2.3

16.1

2.29

28.5

1950

300

200

37/2.6

18.2

2.29

30.5

2386

300

250

61/2.3

20.7

2.29

33.5

2987

200

325

61/2.6

23.4

2.29

36

3698

200

400

61/2.9

26.1

2.29

39

4510

200

500

61/3.2

28.8

2.29

41.5

5356

150

600

91/2.9

31.9

2.79

50

6678

150

800

127/2.8

36.4

2.79

55

8468

150

1000

127/3.2

41.6

2.79

60

10810

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

2001~5000V Three Cores

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

8

7/1.2

3.6

2.29

29

849

300

14

7/1.6

4.8

2.29

32

1246

300

22

7/2.0

6.0

2.29

34

1431

300

38

7/2.6

7.8

2.29

38

2077

300

60

19/2.0

10.0

2.29

42.5

2899

300

100

19/2.6

13.0

2.29

50.5

4514

300

150

37/2.3

16.1

2.29

57.5

6323

200

200

37/2.6

18.2

2.29

62

7659

150

250

61/2.3

20.7

2.29

68

9668

150

325

61/2.6

23.4

2.29

76

12220

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

5001~8000V One Core; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

14

7/1.6

4.8

2.92

17.5

391

300

22

7/2.0

6.0

2.92

19

491

300

38

7/2.6

7.8

2.92

20.5

693

300

60

19/2.0

10.0

2.92

23.5

1003

300

100

19/2.6

13.0

2.92

26.5

1456

300

150

37/2.3

16.1

2.92

30

2018

300

200

37/2.6

18.2

2.92

32

2460

200

250

61/2.3

20.7

2.92

35

3067

200

325

61/2.6

23.4

2.92

37.5

3782

150

400

61/2.9

26.1

2.92

40

4578

150

500

61/3.2

28.8

2.92

43

5452

150

600

91/2.9

31.9

4.45

52

6788

150

800

127/2.8

36.4

4.45

57

8587

150

1000

127/3.2

41.6

4.45

62.5

10940

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

5001~8000V Three Cores; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

14

7/1.6

4.8

2.92

34.5

1263

300

22

7/2.0

6.0

2.92

37

1590

300

38

7/2.6

7.8

2.92

41

2256

300

60

19/2.0

10.0

2.92

47

3274

300

100

19/2.6

13.0

2.92

53.5

4750

200

150

37/2.3

16.1

2.92

60.5

6586

150

200

37/2.6

18.2

2.92

65

8011

150

250

61/2.3

20.7

2.92

71

9970

150

325

61/2.6

23.4

2.92

79

12560

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

5001~8000V One Core; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

14

7/1.6

4.8

3.56

19

460

300

22

7/2.0

6.0

3.56

20

560

300

38

7/2.6

7.8

3.56

23

790

300

60

19/2.0

10.0

3.56

25

1065

300

100

19/2.6

13.0

3.56

28

1525

300

150

37/2.3

16.1

3.56

31

2095

300

200

37/2.6

18.2

3.56

34

2545

200

250

61/2.3

20.7

3.56

36

3155

200

325

61/2.6

23.4

3.56

39

3880

150

400

61/2.9

26.1

3.56

41.5

4680

150

500

61/3.2

28.8

3.56

46

5735

150

600

91/2.9

31.9

4.45

52

6915

150

800

127/2.8

36.4

4.45

57

8725

150

1000

127/3.2

41.6

4.45

62.5

11090

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

5001~8000V Three Cores; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

14

7/1.6

4.8

3.56

37.5

1500

300

22

7/2.0

6.0

3.56

40

1840

300

38

7/2.6

7.8

3.56

43.5

2450

300

60

19/2.0

10.0

3.56

49

3505

300

100

19/2.6

13.0

3.56

56

4990

200

150

37/2.3

16.1

3.56

63

6865

150

200

37/2.6

18.2

3.56

68.5

8320

150

250

61/2.3

20.7

3.56

74

10570

150

325

61/2.6

23.4

3.56

80

12930

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

8001~15000V One Core ; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

4.45

25

856

300

60

19/2.0

10.0

4.45

27

1130

300

100

19/2.6

13.0

4.45

30

1590

200

150

37/2.3

16.1

4.45

34

2167

200

200

37/2.6

18.2

4.45

36

2628

200

250

61/2.3

20.7

4.45

38

3246

200

325

61/2.6

23.4

4.45

41

3976

200

400

61/2.9

26.1

4.45

43.5

4785

150

500

61/3.2

28.8

4.45

48.5

5850

150

600

91/2.9

31.9

5.59

55

7021

150

800

127/2.8

36.4

5.59

59

8841

150

1000

127/3.2

41.6

5.59

65

11220

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

8001~15000V Three Cores; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

4.45

49.5

2840

200

60

19/2.0

10.0

4.45

54

3744

200

100

19/2.6

13.0

4.45

60.5

5084

150

150

37/2.3

16.1

4.45

68.5

7176

150

200

37/2.6

18.2

4.45

73

8441

150

250

61/2.3

20.7

4.45

80

10920

150

325

61/2.6

23.4

4.45

86

13310

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

8001~15000V One Core; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

5.59

27

964

200

60

19/2.0

10.0

5.59

29.5

1244

200

100

19/2.6

13.0

5.59

33

1721

150

150

37/2.3

16.1

5.59

36

2310

150

200

37/2.6

18.2

5.59

38

2767

150

250

61/2.3

20.7

5.59

40.5

3392

150

325

61/2.6

23.4

5.59

45

4130

150

400

61/2.9

26.1

5.59

47.5

5124

150

500

61/3.2

28.8

5.59

50

6031

150

600

91/2.9

31.9

5.59

55

7266

150

800

127/2.8

36.4

5.59

60

9013

150

1000

127/3.2

41.6

5.59

65

11500

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

8001~15000V Three Cores; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

5.59

54.5

3168

150

60

19/2.0

10.0

5.59

59

4098

150

100

19/2.6

13.0

5.59

66.5

5669

150

150

37/2.3

16.1

5.59

73

7606

150

200

37/2.6

18.2

5.59

80

9369

150

250

61/2.3

20.7

5.59

85

11420

150

325

61/2.6

23.4

5.59

91

13960

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

15001~25000V One Core; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

6.6

29.5

1060

300

60

19/2.0

10.0

6.6

32

1340

300

100

19/2.6

13.0

6.6

35

1850

200

150

37/2.3

16.1

6.6

38

2480

200

200

37/2.6

18.2

6.6

40

2940

200

250

61/2.3

20.7

6.6

42.5

3560

200

325

61/2.6

23.4

6.6

47

4500

200

400

61/2.9

26.1

6.6

50

5390

150

500

61/3.2

28.8

6.6

52

6300

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

15001~25000V Three Cores; Neutral Grounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

6.6

59

3520

200

60

19/2.0

10.0

6.6

64

4440

200

100

19/2.6

13.0

6.6

71

6100

150

150

37/2.3

16.1

6.6

80

8410

150

200

37/2.6

18.2

6.6

84

9930

150

250

61/2.3

20.7

6.6

89

11930

150

325

61/2.6

23.4

6.6

96

14480

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

15001~25000V One Core; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

8.76

34.5

1300

200

60

19/2.0

10.0

8.76

36.5

1590

200

100

19/2.6

13.0

8.76

39.5

2100

150

150

37/2.3

16.1

8.76

43

2740

150

200

37/2.6

18.2

8.76

46.5

3370

150

250

61/2.3

20.7

8.76

49

4060

150

325

61/2.6

23.4

8.76

51.5

4880

150

400

61/2.9

26.1

8.76

54

5740

150

500

61/3.2

28.8

8.76

57

6670

150


For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.

XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)

15001~25000V Three Cores; Neutral Ungrounded System

Conductor

Thickness of insulation

mm

Approx.

Overall Diameter

mm

Approx.

Weight

Kg/km

Standard

Length

M

Normative Cross Area

mm2

Number/ Diameter of Wires

No./mm

Outer Diameter

Approx.

mm

38

7/2.6

7.8

8.76

70

4380

150

60

19/2.0

10.0

8.76

76

5620

150

100

19/2.6

13.0

8.76

83

7280

150

150

37/2.3

16.1

8.76

90

9420

150

200

37/2.6

18.2

8.76

94

10980

150

250

61/2.3

20.7

8.76

99

13230

150

325

61/2.6

23.4

8.76

105

15850

150

For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.