600V~25KV Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Sheathed Cables. It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 2655.
Features
Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Conductor screen (voltage >2001V) (3) Insulation: XLPE. (4) Insulation screen (voltage > 2001V) (5) Copper tape shielding (voltage > 2001V) (6) Two or more cores are twisted together,cable core covered with proper separator (7) Sheath: PVC Introduction: Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce XLPE cable in 1967. Signed technical cooperation with “Furukawa Denko K.K. Japan” to produce 33KV XLPE cable in 1977. In 1977, we invested heavily in strippable insulation screen with three tandem extrusions. In 1985, we developed dry curing method for insulated process. 600V~25KV XLPE power cable has labeled our National Quality Standard.
Specifications
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
600V One Core
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
- | 1/1.6 | 1.6 | 0.76 | 4.2 | 49 | 300 |
- | 1/2.0 | 2.0 | 0.76 | 4.6 | 63 | 300 |
- | 1/2.6 | 2.6 | 0.76 | 4.9 | 87 | 300 |
- | 1/3.2 | 3.2 | 1.14 | 6.7 | 128 | 300 |
2.0 | 7/0.6 | 1.8 | 0.76 | 4.4 | 51 | 300 |
3.5 | 7/0.8 | 2.4 | 0.76 | 5.0 | 71 | 300 |
5.5 | 7/1.0 | 3.0 | 0.76 | 5.6 | 94 | 300 |
8 | 7/1.2 | 3.6 | 1.14 | 6.6 | 134 | 300 |
14 | 7/1.6 | 4.8 | 1.14 | 8.6 | 203 | 300 |
22 | 7/2.0 | 6.0 | 1.14 | 9.8 | 288 | 300 |
38 | 7/2.6 | 7.8 | 1.40 | 12.1 | 450 | 300 |
60 | 19/2.0 | 10.0 | 1.40 | 15.6 | 679 | 300 |
100 | 19/2.6 | 13.0 | 1.40 | 18.5 | 1083 | 300 |
150 | 37/2.3 | 16.1 | 1.65 | 23.4 | 1676 | 300 |
200 | 37/2.6 | 18.2 | 1.65 | 25.5 | 2091 | 200 |
250 | 61/2.3 | 20.7 | 1.65 | 28.0 | 2665 | 200 |
325 | 61/2.6 | 23.4 | 2.03 | 31.4 | 3380 | 200 |
400 | 61/2.9 | 26.1 | 2.03 | 34.1 | 4147 | 200 |
500 | 61/3.2 | 28.8 | 2.03 | 36.8 | 4990 | 150 |
600 | 91/2.9 | 31.9 | 2.41 | 38.5 | 6105 | 150 |
800 | 127/2.8 | 36.4 | 2.41 | 46.9 | 7883 | 150 |
1000 | 127/3.2 | 41.6 | 2.41 | 52.1 | 10160 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
600V Two Cores
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
- | 1/1.6 | 1.6 | 0.76 | 9.4 | 110 | 300 |
- | 1/2.0 | 2.0 | 0.76 | 10.2 | 140 | 300 |
- | 1/2.6 | 2.6 | 0.76 | 11.4 | 195 | 300 |
- | 1/3.2 | 3.2 | 1.14 | 14.4 | 322 | 300 |
2.0 | 7/0.6 | 1.8 | 0.76 | 9.8 | 116 | 300 |
3.5 | 7/0.8 | 2.4 | 0.76 | 11.0 | 160 | 300 |
5.5 | 7/1.0 | 3.0 | 0.76 | 12.2 | 213 | 300 |
8 | 7/1.2 | 3.6 | 1.14 | 16.0 | 341 | 300 |
14 | 7/1.6 | 4.8 | 1.14 | 18.4 | 502 | 300 |
22 | 7/2.0 | 6.0 | 1.14 | 20.8 | 699 | 300 |
38 | 7/2.6 | 7.8 | 1.40 | 26.6 | 927 | 300 |
60 | 19/2.0 | 10.0 | 1.40 | 31.0 | 1683 | 300 |
100 | 19/2.6 | 13.0 | 1.40 | 36.8 | 2615 | 300 |
150 | 37/2.3 | 16.1 | 1.65 | 46.3 | 4053 | 300 |
200 | 37/2.6 | 18.2 | 1.65 | 50.3 | 5003 | 300 |
250 | 61/2.3 | 20.7 | 1.65 | 55.3 | 6313 | 200 |
325 | 61/2.6 | 23.4 | 2.03 | 62.1 | 7985 | 200 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
600V Three Cores
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
- | 1/1.6 | 1.6 | 0.76 | 9.9 | 135 | 300 |
- | 1/2.0 | 2.0 | 0.76 | 10.8 | 177 | 300 |
- | 1/2.6 | 2.6 | 0.76 | 12.1 | 253 | 300 |
- | 1/3.2 | 3.2 | 1.14 | 16.1 | 414 | 300 |
2.0 | 7/0.6 | 1.8 | 0.76 | 10.4 | 142 | 300 |
3.5 | 7/0.8 | 2.4 | 0.76 | 11.6 | 200 | 300 |
5.5 | 7/1.0 | 3.0 | 0.76 | 12.9 | 272 | 300 |
8 | 7/1.2 | 3.6 | 1.14 | 17.0 | 431 | 300 |
14 | 7/1.6 | 4.8 | 1.14 | 19.5 | 649 | 300 |
22 | 7/2.0 | 6.0 | 1.14 | 25.1 | 971 | 300 |
38 | 7/2.6 | 7.8 | 1.40 | 28.3 | 1533 | 300 |
60 | 19/2.0 | 10.0 | 1.40 | 33.0 | 2271 | 300 |
100 | 19/2.6 | 13.0 | 1.40 | 39.3 | 3604 | 300 |
150 | 37/2.3 | 16.1 | 1.65 | 49.4 | 5560 | 300 |
200 | 37/2.6 | 18.2 | 1.65 | 53.7 | 6907 | 200 |
250 | 61/2.3 | 20.7 | 1.65 | 59.1 | 8769 | 200 |
325 | 61/2.6 | 23.4 | 2.03 | 66.5 | 11120 | 200 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
600V Four Cores
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
- | 1/1.6 | 1.6 | 0.76 | 10.7 | 166 | 300 |
- | 1/2.0 | 2.0 | 0.76 | 11.7 | 219 | 300 |
- | 1/2.6 | 2.6 | 0.76 | 13.1 | 317 | 300 |
- | 1/3.2 | 3.2 | 1.14 | 16.8 | 488 | 300 |
2.0 | 7/0.6 | 1.8 | 0.76 | 11.2 | 174 | 300 |
3.5 | 7/0.8 | 2.4 | 0.76 | 12.7 | 252 | 300 |
5.5 | 7/1.0 | 3.0 | 0.76 | 14.9 | 373 | 300 |
8 | 7/1.2 | 3.6 | 1.14 | 18.5 | 545 | 300 |
14 | 7/1.6 | 4.8 | 1.14 | 22.4 | 885 | 300 |
22 | 7/2.0 | 6.0 | 1.14 | 25.3 | 1251 | 300 |
38 | 7/2.6 | 7.8 | 1.40 | 31.1 | 1960 | 300 |
60 | 19/2.0 | 10.0 | 1.40 | 36.4 | 2943 | 300 |
100 | 19/2.6 | 13.0 | 1.40 | 45.1 | 4845 | 300 |
150 | 37/2.3 | 16.1 | 1.65 | 54.5 | 7191 | 200 |
200 | 37/2.6 | 18.2 | 1.65 | 59.4 | 8961 | 200 |
250 | 61/2.3 | 20.7 | 1.65 | 65.4 | 11400 | 200 |
325 | 61/2.6 | 23.4 | 2.03 | 75.2 | 14760 | 200 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
601~2000V One Core
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
2.0 | 7/0.6 | 1.8 | 1.14 | 7.3 | 56 | 300 |
3.5 | 7/0.8 | 2.4 | 1.14 | 7.9 | 74 | 300 |
5.5 | 7/1.0 | 3.0 | 1.14 | 8.4 | 98 | 300 |
8 | 7/1.2 | 3.6 | 1.40 | 9.6 | 133 | 300 |
14 | 7/1.6 | 4.8 | 1.40 | 11.6 | 200 | 300 |
22 | 7/2.0 | 6.0 | 1.40 | 12.8 | 284 | 300 |
38 | 7/2.6 | 7.8 | 1.65 | 15.6 | 451 | 300 |
60 | 19/2.0 | 10.0 | 1.65 | 18.6 | 690 | 300 |
100 | 19/2.6 | 13.0 | 1.65 | 21.6 | 1098 | 300 |
150 | 37/2.3 | 16.1 | 1.90 | 26.3 | 1692 | 300 |
200 | 37/2.6 | 18.2 | 1.90 | 28.4 | 2111 | 300 |
250 | 61/2.3 | 20.7 | 1.90 | 30.9 | 2669 | 200 |
325 | 61/2.6 | 23.4 | 2.29 | 34.4 | 3391 | 200 |
400 | 61/2.9 | 26.1 | 2.29 | 37.1 | 4154 | 200 |
500 | 61/3.2 | 28.8 | 2.29 | 39.7 | 4996 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
601~2000V Three Cores
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
2.0 | 7/0.6 | 1.8 | 1.14 | 13.8 | 179 | 300 |
3.5 | 7/0.8 | 2.4 | 1.14 | 15.0 | 241 | 300 |
5.5 | 7/1.0 | 3.0 | 1.14 | 18.0 | 348 | 300 |
8 | 7/1.2 | 3.6 | 1.40 | 20.5 | 473 | 300 |
14 | 7/1.6 | 4.8 | 1.40 | 23.0 | 698 | 300 |
22 | 7/2.0 | 6.0 | 1.40 | 28.0 | 1040 | 300 |
38 | 7/2.6 | 7.8 | 1.65 | 32.8 | 1615 | 300 |
60 | 19/2.0 | 10.0 | 1.65 | 37.5 | 2363 | 300 |
100 | 19/2.6 | 13.0 | 1.65 | 44.0 | 3703 | 300 |
125 | 19/2.9 | 14.5 | 1.90 | 51.8 | 4751 | 200 |
150 | 37/2.3 | 16.1 | 1.90 | 55.3 | 5671 | 200 |
200 | 37/2.6 | 18.2 | 1.90 | 60.0 | 7039 | 150 |
250 | 61/2.3 | 20.7 | 1.90 | 65.0 | 8853 | 150 |
325 | 61/2.6 | 23.4 | 2.29 | 73.0 | 11240 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
2001~5000V One Core
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
8 | 7/1.2 | 3.6 | 2.29 | 14 | 244 | 300 |
14 | 7/1.6 | 4.8 | 2.29 | 16 | 330 | 300 |
22 | 7/2.0 | 6.0 | 2.29 | 17.5 | 448 | 300 |
38 | 7/2.6 | 7.8 | 2.29 | 19 | 644 | 300 |
60 | 19/2.0 | 10.0 | 2.29 | 21 | 897 | 300 |
100 | 19/2.6 | 13.0 | 2.29 | 25 | 1393 | 300 |
150 | 37/2.3 | 16.1 | 2.29 | 28.5 | 1950 | 300 |
200 | 37/2.6 | 18.2 | 2.29 | 30.5 | 2386 | 300 |
250 | 61/2.3 | 20.7 | 2.29 | 33.5 | 2987 | 200 |
325 | 61/2.6 | 23.4 | 2.29 | 36 | 3698 | 200 |
400 | 61/2.9 | 26.1 | 2.29 | 39 | 4510 | 200 |
500 | 61/3.2 | 28.8 | 2.29 | 41.5 | 5356 | 150 |
600 | 91/2.9 | 31.9 | 2.79 | 50 | 6678 | 150 |
800 | 127/2.8 | 36.4 | 2.79 | 55 | 8468 | 150 |
1000 | 127/3.2 | 41.6 | 2.79 | 60 | 10810 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
2001~5000V Three Cores
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
8 | 7/1.2 | 3.6 | 2.29 | 29 | 849 | 300 |
14 | 7/1.6 | 4.8 | 2.29 | 32 | 1246 | 300 |
22 | 7/2.0 | 6.0 | 2.29 | 34 | 1431 | 300 |
38 | 7/2.6 | 7.8 | 2.29 | 38 | 2077 | 300 |
60 | 19/2.0 | 10.0 | 2.29 | 42.5 | 2899 | 300 |
100 | 19/2.6 | 13.0 | 2.29 | 50.5 | 4514 | 300 |
150 | 37/2.3 | 16.1 | 2.29 | 57.5 | 6323 | 200 |
200 | 37/2.6 | 18.2 | 2.29 | 62 | 7659 | 150 |
250 | 61/2.3 | 20.7 | 2.29 | 68 | 9668 | 150 |
325 | 61/2.6 | 23.4 | 2.29 | 76 | 12220 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
5001~8000V One Core; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
14 | 7/1.6 | 4.8 | 2.92 | 17.5 | 391 | 300 |
22 | 7/2.0 | 6.0 | 2.92 | 19 | 491 | 300 |
38 | 7/2.6 | 7.8 | 2.92 | 20.5 | 693 | 300 |
60 | 19/2.0 | 10.0 | 2.92 | 23.5 | 1003 | 300 |
100 | 19/2.6 | 13.0 | 2.92 | 26.5 | 1456 | 300 |
150 | 37/2.3 | 16.1 | 2.92 | 30 | 2018 | 300 |
200 | 37/2.6 | 18.2 | 2.92 | 32 | 2460 | 200 |
250 | 61/2.3 | 20.7 | 2.92 | 35 | 3067 | 200 |
325 | 61/2.6 | 23.4 | 2.92 | 37.5 | 3782 | 150 |
400 | 61/2.9 | 26.1 | 2.92 | 40 | 4578 | 150 |
500 | 61/3.2 | 28.8 | 2.92 | 43 | 5452 | 150 |
600 | 91/2.9 | 31.9 | 4.45 | 52 | 6788 | 150 |
800 | 127/2.8 | 36.4 | 4.45 | 57 | 8587 | 150 |
1000 | 127/3.2 | 41.6 | 4.45 | 62.5 | 10940 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
5001~8000V Three Cores; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
14 | 7/1.6 | 4.8 | 2.92 | 34.5 | 1263 | 300 |
22 | 7/2.0 | 6.0 | 2.92 | 37 | 1590 | 300 |
38 | 7/2.6 | 7.8 | 2.92 | 41 | 2256 | 300 |
60 | 19/2.0 | 10.0 | 2.92 | 47 | 3274 | 300 |
100 | 19/2.6 | 13.0 | 2.92 | 53.5 | 4750 | 200 |
150 | 37/2.3 | 16.1 | 2.92 | 60.5 | 6586 | 150 |
200 | 37/2.6 | 18.2 | 2.92 | 65 | 8011 | 150 |
250 | 61/2.3 | 20.7 | 2.92 | 71 | 9970 | 150 |
325 | 61/2.6 | 23.4 | 2.92 | 79 | 12560 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
5001~8000V One Core; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
14 | 7/1.6 | 4.8 | 3.56 | 19 | 460 | 300 |
22 | 7/2.0 | 6.0 | 3.56 | 20 | 560 | 300 |
38 | 7/2.6 | 7.8 | 3.56 | 23 | 790 | 300 |
60 | 19/2.0 | 10.0 | 3.56 | 25 | 1065 | 300 |
100 | 19/2.6 | 13.0 | 3.56 | 28 | 1525 | 300 |
150 | 37/2.3 | 16.1 | 3.56 | 31 | 2095 | 300 |
200 | 37/2.6 | 18.2 | 3.56 | 34 | 2545 | 200 |
250 | 61/2.3 | 20.7 | 3.56 | 36 | 3155 | 200 |
325 | 61/2.6 | 23.4 | 3.56 | 39 | 3880 | 150 |
400 | 61/2.9 | 26.1 | 3.56 | 41.5 | 4680 | 150 |
500 | 61/3.2 | 28.8 | 3.56 | 46 | 5735 | 150 |
600 | 91/2.9 | 31.9 | 4.45 | 52 | 6915 | 150 |
800 | 127/2.8 | 36.4 | 4.45 | 57 | 8725 | 150 |
1000 | 127/3.2 | 41.6 | 4.45 | 62.5 | 11090 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
5001~8000V Three Cores; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
14 | 7/1.6 | 4.8 | 3.56 | 37.5 | 1500 | 300 |
22 | 7/2.0 | 6.0 | 3.56 | 40 | 1840 | 300 |
38 | 7/2.6 | 7.8 | 3.56 | 43.5 | 2450 | 300 |
60 | 19/2.0 | 10.0 | 3.56 | 49 | 3505 | 300 |
100 | 19/2.6 | 13.0 | 3.56 | 56 | 4990 | 200 |
150 | 37/2.3 | 16.1 | 3.56 | 63 | 6865 | 150 |
200 | 37/2.6 | 18.2 | 3.56 | 68.5 | 8320 | 150 |
250 | 61/2.3 | 20.7 | 3.56 | 74 | 10570 | 150 |
325 | 61/2.6 | 23.4 | 3.56 | 80 | 12930 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
8001~15000V One Core ; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 4.45 | 25 | 856 | 300 |
60 | 19/2.0 | 10.0 | 4.45 | 27 | 1130 | 300 |
100 | 19/2.6 | 13.0 | 4.45 | 30 | 1590 | 200 |
150 | 37/2.3 | 16.1 | 4.45 | 34 | 2167 | 200 |
200 | 37/2.6 | 18.2 | 4.45 | 36 | 2628 | 200 |
250 | 61/2.3 | 20.7 | 4.45 | 38 | 3246 | 200 |
325 | 61/2.6 | 23.4 | 4.45 | 41 | 3976 | 200 |
400 | 61/2.9 | 26.1 | 4.45 | 43.5 | 4785 | 150 |
500 | 61/3.2 | 28.8 | 4.45 | 48.5 | 5850 | 150 |
600 | 91/2.9 | 31.9 | 5.59 | 55 | 7021 | 150 |
800 | 127/2.8 | 36.4 | 5.59 | 59 | 8841 | 150 |
1000 | 127/3.2 | 41.6 | 5.59 | 65 | 11220 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
8001~15000V Three Cores; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 4.45 | 49.5 | 2840 | 200 |
60 | 19/2.0 | 10.0 | 4.45 | 54 | 3744 | 200 |
100 | 19/2.6 | 13.0 | 4.45 | 60.5 | 5084 | 150 |
150 | 37/2.3 | 16.1 | 4.45 | 68.5 | 7176 | 150 |
200 | 37/2.6 | 18.2 | 4.45 | 73 | 8441 | 150 |
250 | 61/2.3 | 20.7 | 4.45 | 80 | 10920 | 150 |
325 | 61/2.6 | 23.4 | 4.45 | 86 | 13310 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
8001~15000V One Core; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 5.59 | 27 | 964 | 200 |
60 | 19/2.0 | 10.0 | 5.59 | 29.5 | 1244 | 200 |
100 | 19/2.6 | 13.0 | 5.59 | 33 | 1721 | 150 |
150 | 37/2.3 | 16.1 | 5.59 | 36 | 2310 | 150 |
200 | 37/2.6 | 18.2 | 5.59 | 38 | 2767 | 150 |
250 | 61/2.3 | 20.7 | 5.59 | 40.5 | 3392 | 150 |
325 | 61/2.6 | 23.4 | 5.59 | 45 | 4130 | 150 |
400 | 61/2.9 | 26.1 | 5.59 | 47.5 | 5124 | 150 |
500 | 61/3.2 | 28.8 | 5.59 | 50 | 6031 | 150 |
600 | 91/2.9 | 31.9 | 5.59 | 55 | 7266 | 150 |
800 | 127/2.8 | 36.4 | 5.59 | 60 | 9013 | 150 |
1000 | 127/3.2 | 41.6 | 5.59 | 65 | 11500 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
8001~15000V Three Cores; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 5.59 | 54.5 | 3168 | 150 |
60 | 19/2.0 | 10.0 | 5.59 | 59 | 4098 | 150 |
100 | 19/2.6 | 13.0 | 5.59 | 66.5 | 5669 | 150 |
150 | 37/2.3 | 16.1 | 5.59 | 73 | 7606 | 150 |
200 | 37/2.6 | 18.2 | 5.59 | 80 | 9369 | 150 |
250 | 61/2.3 | 20.7 | 5.59 | 85 | 11420 | 150 |
325 | 61/2.6 | 23.4 | 5.59 | 91 | 13960 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
15001~25000V One Core; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 6.6 | 29.5 | 1060 | 300 |
60 | 19/2.0 | 10.0 | 6.6 | 32 | 1340 | 300 |
100 | 19/2.6 | 13.0 | 6.6 | 35 | 1850 | 200 |
150 | 37/2.3 | 16.1 | 6.6 | 38 | 2480 | 200 |
200 | 37/2.6 | 18.2 | 6.6 | 40 | 2940 | 200 |
250 | 61/2.3 | 20.7 | 6.6 | 42.5 | 3560 | 200 |
325 | 61/2.6 | 23.4 | 6.6 | 47 | 4500 | 200 |
400 | 61/2.9 | 26.1 | 6.6 | 50 | 5390 | 150 |
500 | 61/3.2 | 28.8 | 6.6 | 52 | 6300 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
15001~25000V Three Cores; Neutral Grounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 6.6 | 59 | 3520 | 200 |
60 | 19/2.0 | 10.0 | 6.6 | 64 | 4440 | 200 |
100 | 19/2.6 | 13.0 | 6.6 | 71 | 6100 | 150 |
150 | 37/2.3 | 16.1 | 6.6 | 80 | 8410 | 150 |
200 | 37/2.6 | 18.2 | 6.6 | 84 | 9930 | 150 |
250 | 61/2.3 | 20.7 | 6.6 | 89 | 11930 | 150 |
325 | 61/2.6 | 23.4 | 6.6 | 96 | 14480 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
15001~25000V One Core; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 8.76 | 34.5 | 1300 | 200 |
60 | 19/2.0 | 10.0 | 8.76 | 36.5 | 1590 | 200 |
100 | 19/2.6 | 13.0 | 8.76 | 39.5 | 2100 | 150 |
150 | 37/2.3 | 16.1 | 8.76 | 43 | 2740 | 150 |
200 | 37/2.6 | 18.2 | 8.76 | 46.5 | 3370 | 150 |
250 | 61/2.3 | 20.7 | 8.76 | 49 | 4060 | 150 |
325 | 61/2.6 | 23.4 | 8.76 | 51.5 | 4880 | 150 |
400 | 61/2.9 | 26.1 | 8.76 | 54 | 5740 | 150 |
500 | 61/3.2 | 28.8 | 8.76 | 57 | 6670 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.
XLPE Insulated and Polyvinyl Chloride Sheathed Cables (CV)
15001~25000V Three Cores; Neutral Ungrounded System
Conductor | Thickness of insulation mm | Approx. Overall Diameter mm | Approx. Weight Kg/km | Standard Length M | ||
Normative Cross Area mm2 | Number/ Diameter of Wires No./mm | Outer Diameter Approx. mm | ||||
38 | 7/2.6 | 7.8 | 8.76 | 70 | 4380 | 150 |
60 | 19/2.0 | 10.0 | 8.76 | 76 | 5620 | 150 |
100 | 19/2.6 | 13.0 | 8.76 | 83 | 7280 | 150 |
150 | 37/2.3 | 16.1 | 8.76 | 90 | 9420 | 150 |
200 | 37/2.6 | 18.2 | 8.76 | 94 | 10980 | 150 |
250 | 61/2.3 | 20.7 | 8.76 | 99 | 13230 | 150 |
325 | 61/2.6 | 23.4 | 8.76 | 105 | 15850 | 150 |
For conductor area large than 8 mm2, both compressed and compact stranded conductors are available.